•  Hangzhou Hangrui Power Automation Co., Ltd
  •  Hangzhou Hangrui Power Automation Co., Ltd
  •  Hangzhou Hangrui Power Automation Co., Ltd
  •  Hangzhou Hangrui Power Automation Co., Ltd
  •  Hangzhou Hangrui Power Automation Co., Ltd
  •  Hangzhou Hangrui Power Automation Co., Ltd
  •  Hangzhou Hangrui Power Automation Co., Ltd
  •  Hangzhou Hangrui Power Automation Co., Ltd

Company Profile

detailed

Hangzhou Hangrui Power Automation Co., Ltd. is mainly engaged in the R&D and production of 110KV and below substation integrated automation system, power plant integrated automation system, hydropower station integrated automation system, dispatching integrated automation system, industrial control automation system pin Sales and service, development and development of various series and specifications of products to meet different user requirements.  

Miss Huang

Online contact

Mobile: 13175671188

Address: Room 201, Unit 2, No. 64, Tiancheng Road, Jianggan District, Hangzhou, Zhejiang

Product recommendation

News Center

more
  • NARI relay protection device power panel display screen

    1.2 Technical data 1.2.1 Rated data DC power supply: 220V, 110V Allowable deviation: 15%, - 20% AC voltage: 100/3V (phase voltage), 100V (line voltage) AC current: 5A, 1A frequency: 50Hz 1.2.2 Power consumption AC voltage: AC current: DC: normal tripping 1.2.3 Main technical indicators (1) Definite time overcurrent a) Fixed value of phase current: 0.1In ~ 20Inb) Fixed value of zero sequence current: 0.02 ~ 12.00Ac) Fixed value of time: 0.0 ~ 100.0Sd) Fixed value error of current: e) Fixed value of time

    2024/04/17 15:55:46
  • Nanjing NARI PCS9611 9621 power panel display screen

    1.1 The basic configuration RCS-9611B is applicable to the protection, measurement and control of the feeder line in the low current grounding system (neutral point ungrounded or grounded through arc suppression coil system) with a voltage level below 35kV and the neutral point grounded through resistance. It can be installed in panel assembly or locally in the switchgear. (1) Main functions of protection a) Three section fixed time limit directional overcurrent protection that can be locked by low-voltage (the third section can be set as inverse time limit, and three inverse time limit characteristics can be selected, and the inverse time limit can also be locked by direction or low-voltage); b) Three section zero sequence overcurrent protection (zero sequence current can be applied externally or from

    2024/04/17 15:52:36
  • Guodian Nanzi PSM642UX microcomputer protection

    Menu description The keyboard operation and LCD display interface of the low-voltage protection and measurement and control platform device adopt the operation mode of dialog box combined with menu. LCD is two-color, 192 * 64 dot matrix graphic display. 12 * 12 dot matrix font is adopted. Schematic diagram of overall structure of display screen Note: menu items marked with ★ are responsible for executing specific functions! 2.1 Menu structure 2.1.1 Effective value of operation status: real-time display of effective value and phase angle of each analog channel; Input quantity: display the status of each input quantity in real time; Measurement value: real-time display of the size of each measurement; Electrical measurement: real-time display of the size of each electrical measurement; Calculation amount: real-time display

    2023/12/28 13:20:08
  • Guodian Nanzi PSM642UX protection device

    1.4 Measurement and control and other functions 1.4.1 Measurement and control function a. Telemetry is mainly used to measure voltage, current, zero sequence current, active power, reactive power, power factor, frequency, etc., and can calculate active and reactive electrical degrees. According to the number of connected measuring current channels, you can set whether to use the two meter method or the three meter method to measure power in the "operating parameters". b. Calibration of measuring channel 1) External AC terminal wiring: measuring current (including phase current and zero sequence current) circuit terminals are connected in series and voltage terminals are connected in parallel (PSP641U requires three-phase symmetrical voltage). 2) Offset calibration: external AC terminal

    2023/12/28 10:51:01
  • Guodian Nanzi PSM642UX

    1.2.8 Technical performance of measurement and control function a. Measurement accuracy of power frequency analog quantity - AC voltage and AC current: ± 0.2% (level 0.2), - active power and reactive power: ± 0.5% (level 0.5), - phase angle or power factor: ± 0.5% (level 0.5), - frequency: ± 0.01Hz; b) Measurement range of power frequency analog quantity - current: (0 ~ 1.2) IN, - voltage: (0 ~ 1.2) × 100V, - three-phase active power: - (1.2 × UN. L3) INW ~ + (1.2 × UN. L3) INW, - three-phase active power: - 1.2

    2023/12/28 10:43:16
  • Guodian Nanzi PST645UX

    1 Overview 1.1 Scope of application PS640UX series protection, measurement and control device is an integrated protection, measurement and control device developed by Guodian Nanjing Automation Co., Ltd. for power, petrochemical, steel, metallurgy and other industries. It is applicable to local power and industrial systems with non direct grounding or small resistance grounding systems with voltage levels below 110kV. Based on the ZYNQ platform independently developed by Guodian Nanzi, the PS640UX series protection, measurement and control device adopts a number of innovative technologies, integrates protection, control, measurement, communication and monitoring functions, and is rich in resources, complete in configuration, flexible in operation and maintenance, stable, reliable and safe

    2023/12/25 13:51:20
I want to join