Oil and gas storage and transportation network

  Retrieve password
  Register Now

 QQ login

QQ quick login

Start quickly in one step

 Pdms training&project Digital 360 network

Flare and vent calculation

Online calculation program of noise intensity Lp when the distance between flare and discharge point exceeds 30m
Reference standard: HG/T 20570.12-95 Flare System Setup P17 (411) according to the formula LP=L30-20lg( γ I/30), where di is the inner diameter of the heat exchanger, m; No Number of heat exchange tubes per pass; F is the sectional area of pipe passage, m2
2013-4-20 21:05
Online calculation program of noise intensity L30 at 30m away from the discharge point in flare calculation
 Online calculation program of noise intensity L30 at 30m away from the discharge point in flare calculation
Reference standard: HG/T 20570.12-95 Flare System Setting P17 (411) is calculated according to the formula L30=L+10lg (WC2/2). Where, L30 is the noise intensity 30 m away from the emission point, dB; L is the noise intensity, dB, which can be seen from Figure 1; W is the discharge flare gas flow, kg/s; C is the sound velocity, m/s (see
2013-4-20 20:46
Online calculation program of flare stack height (used for Brutowski/Sommer approximate calculation method)
 Online calculation program of flare stack height (used for Brutowski/Sommer approximate calculation method)
Reference standard: HG/T 20570.12-95 Flare System Setting P15 (409) According to the formula H=0.5 - YC, H is the height of flare stack, m; D is the distance from the flame center to the ground boundary, m; For the calculation of D, see the online calculation program of distance D from the torch flame center to the ground boundary, R is the radius of the barrier free area, m
2013-4-19 22:21
Online calculation program for calculating wind thrust and jet thrust djR of flare (used for Brutowski/Sommer approximate calculation method)
 Online calculation program for calculating wind thrust and jet thrust djR of flare (used for Brutowski/Sommer approximate calculation method)
Reference standard: HG/T 20570.12-95 Flare System Setup P13 (407) is calculated according to the formula, where dj is the diameter of the flame stack, m; Uj is the outlet velocity of flame gas, m/s; Ux is the design wind speed, m/s; Tx is the air temperature, K; Tj is flame gas temperature, K; Mj is the average molecular weight of flame gas
2013-4-19 21:54
On line calculation program of lower explosion limit parameters of flare gas (used for Brutowski/Sommer approximate calculation method)
 On line calculation program of lower explosion limit parameters of flare gas (used for Brutowski/Sommer approximate calculation method)
Reference standard: HG/T 20570.12-95 Flare System Settings P12 (406) is calculated according to the formula, where is the lower explosion limit parameter of flame gas, without unit; Cl is the lower explosion limit of flare gas in air, without unit; Uj is the outlet velocity of flare gas, m/s; Ux is the design wind speed, m/s; Mj is the average molecule of flare gas
2013-4-19 20:07
On line calculation program of sound velocity C in flare calculation
 On line calculation program of sound velocity C in flare calculation
Reference standard: HG/T 20570.12-95 Flare System Setting P12 (406) is calculated according to the formula. Wherein, Mj is the average molecular weight of flare gas, without unit; Tj is flare gas temperature, K; Kj is the insulation index of flare gas, without unit; C is sound velocity, m/s;
2013-4-19 19:33
Online calculation program of flare stack height H (for simple approximate calculation)
 Online calculation program of flare stack height H (for simple approximate calculation)
Reference standard: HG/T 20570.12-95 Flare System Setting P12 (406) According to the formula H=0.5 - △ Y/2, where H is the height of flare stack, m; D is the distance from the flame center to the ground boundary, m; For the calculation of D, see the online calculation program of distance D from the torch flame center to the ground boundary, R is the radius of the barrier free area
2013-4-19 11:02
Online calculation program of flame gas velocity Uj at flare stack outlet (for simple approximate calculation)
 Online calculation program of flame gas velocity Uj at flare stack outlet (for simple approximate calculation)
Calculate according to the formula, where Uj is the velocity of flare gas at the outlet of flare stack, m/s; V is the flare gas volume flow, m3/s; Dj is the inner diameter of flare stack top, m;
2013-4-18 21:34
Online calculation program for volume flow V of flare stack (for simple approximate calculation)
 Online calculation program for volume flow V of flare stack (for simple approximate calculation)
Reference standard: HG/T 20570.12-95 Flare System Setting P10 (404) is calculated according to the formula. Wherein, Mj is the average molecular weight of flare gas, without unit; Tj is flare gas temperature, K; Wj is the discharge flow of flare gas, kg/s; V is the volume flow of flare stack, m3/s;
2013-4-18 21:15
The online calculation program of the distance D from the torch flame center to the ground boundary (applicable to simple calculation and Brutowski/Sommer near
 The online calculation program of the distance D from the torch flame center to the ground boundary (applicable to simple calculation and Brutowski/Sommer near
Applicable to simple calculation and Brutowski/Sommer approximate calculation method, where D is the distance from the flame center to the ground boundary, m; τ Is the heat radiation intensity transfer factor, without unit; F is the thermal radiation factor, without unit; Q is the heat release of flare gas, kW; K is the maximum allowable thermal radiation intensity, kW/m2;
2013-4-18 20:49
Online calculation of flare stack diameter dj (applicable to simple calculation and Brutowski/Sommer approximate calculation method)
 Online calculation of flare stack diameter dj (applicable to simple calculation and Brutowski/Sommer approximate calculation method)
Reference standard: HG/T 20570.12-95 Flare System Setting P12 (406) is calculated according to the formula, where Wj is the flare gas discharge flow, kg/s; Pj is the pressure of flare gas inside the top of flare, kPa; Mach is Mach number, which is the ratio of flare gas flow rate and sound velocity of the fluid, dimensionless; Mj is the