Level B vault door As the higher level of the vault door, it adopts a 10mm steel plate Seamless, which not only makes the appearance of the vault door more fashionable, but also has stronger resistance to destruction. Therefore, its anti riot time can reach 60 minutes, and its fireproof time can reach 240 minutes. It has a variety of locks, which can be matched Mechanical lock , double lock Electronic lock 、 Fingerprint lock , iris meter, etc. Because of the irregular matching, it is more difficult for criminals to steal.
Manufacturing process of Level B vault door:
Blanking: The factory usually purchases large steel plates, so one procedure is to cut these plates into the specifications and dimensions required by consumers.
Forming: process the cut steel plate through various machines and equipment such as punch, mold, bending machine, etc. to produce various accessories such as door plate, motor parts, back plate, etc.
Welding: weld various shaped accessories, so that the door body is basically formed
Surface treatment: the blank of the vault door is polished by some meticulous processes, and then the surface is sprayed with plastic. Because the surface is still covered with rust spots and oil stains, phosphating treatment is required to achieve the purpose of degreasing and rust removal, and polishing is smooth. After ZUI, high-temperature electrostatic spraying treatment is carried out, and the surface is painted.
Assembly: assemble the processed treasury door with locks (door locks, emergency locks, password locks), operation panels, mechanisms (including door bolts, handles, etc.), back covers, and accessories (labels, instructions, etc.).
General inspection: after all these are handled, the product will pass the inspection of professionals before it can be determined whether it is qualified or not. If it is unqualified, it will be required to modify it. If it is qualified, it can be packaged and marketed.
Solution to the failure of opening the door of Level B vault:
Electronic lock: one possibility, the battery is dead
Specifically, when the password is entered, the LCD screen displays "OPEN" or a short blue screen appears, and a box keeps running back and forth.
Solution: use the emergency power box to install the battery, insert it into the emergency power hole, and then input the password set by yourself. Just open the door. Don't forget to replace the battery after opening the door.
The second possibility: incorrect password
When we input the password without displaying "OPEN" or automatically start the emergency signal after continuous input, we can directly use the emergency key together with the master key to open the door.
Mechanical lock: mechanical password replacement requires opening the internal device of the password lock. Users without such knowledge need professional guidance.