Kaiyuan automatic exhaust valve
Kaiyuan automatic exhaust valve
 XD371X-16Q signal butterfly valve
XD371X-16Q signal butterfly valve
 Liquid chlorine lining fluorine ball valve
Liquid chlorine lining fluorine ball valve
 Stainless steel liquid ammonia stop valve
Stainless steel liquid ammonia stop valve
 Soft seal wafer butterfly valve
Soft seal wafer butterfly valve
 Double eccentric pneumatic high-performance butterfly valve
Double eccentric pneumatic high-performance butterfly valve
 Low temperature ball valve
Low temperature ball valve
 Stainless steel ammonia stop valve
Stainless steel ammonia stop valve
 A105 forged thread liquid ammonia stop valve
A105 forged thread liquid ammonia stop valve
 Pneumatic O-ring ball valve
Pneumatic O-ring ball valve
 Hydrochloric acid fluorine lined electric ball valve
Hydrochloric acid fluorine lined electric ball valve
 Power off reset electric butterfly valve
Power off reset electric butterfly valve
 Ammonia liquid stop valve
Ammonia liquid stop valve
 Pneumatic cryogenic ball valve
Pneumatic cryogenic ball valve
 ammonia valve
ammonia valve
 Vehicle emergency shut-off valve
Vehicle emergency shut-off valve
 Hydraulic cut-off valve
Hydraulic cut-off valve
 VENT pipe flame arrester
VENT pipe flame arrester

Contact Yonglong

Consulting hotline 021-57566219
  • Mobile: 15900658318
  • Fax: 021-57568296
  • Email: 1257073858@qq.com
  • Address: Nanting Highway, Fengxian District, Shanghai
  • 2788

How to correctly select the electric valve_Yonglong electric shut-off valve

Time: 2021-06-26 23:03:34 Source: Yonglong Valve Reading: zero second
How to correctly select the electric valve_Yonglong electric shut-off valve
In pipeline engineering, the correct selection of electric valves is one of the guarantee conditions to meet the use requirements. If the electric valve used is improperly selected, it will not only affect the use, but also bring adverse consequences or serious losses. So, how do we use the electric valve correctly?
1、 What is an electric valve?
The electric valve is simply to control the valve with the electric actuator, and the actuator is driven by the power supply to open and close the valve. It can be divided into two parts, the upper part is the electric actuator, and the lower part is the valve.
The electric valve is an electric device in the automatic control system, which can not only realize the switch function, but also realize the valve position adjustment function of the regulating electric valve. The travel of electric actuator can be divided into 90 ° angle travel and straight travel. Special requirements can also meet the full travel of 180 °, 270 ° and 360 °. The angle travel electric actuator is used together with the angle travel valve to realize the valve 90 ° internal rotation to control the pipeline fluid on and off; The straight stroke electric actuator is used together with the straight stroke valve to realize the up and down movement of the valve plate to control the flow on and off of the pipeline.
At present, the commonly used electric valves in the market are: Ball Valve , electric butterfly valve, electric gate valve Electric shut-off valve Electric stop valve, electric diaphragm valve, electric plug valve, electric emergency cut-off valve and other products. For example, the liquid ammonia electric emergency shut-off valve produced by Shanghai Yonglong Valve Factory, Electric low-temperature ball valve The angle travel explosion-proof electric actuator is used, while the conduction oil electric shut-off valve and the steam electric shut-off valve use the straight travel electric actuator.
 Explosion proof electric ball valve Shanghai Yonglong
Explosion proof electric ball valve Shanghai Yonglong
2、 Technical principle:
The electric valve is usually connected by the electric actuator and the valve, and becomes the electric valve after installation and commissioning. The electric valve uses electric energy as power to connect the electric actuator to drive the valve, and the opening and closing and regulating actions of the valve are controlled by 4~20 current signals. So as to achieve the purpose of switching or regulating the pipeline medium.
The drive of the electric valve is usually driven by a motor. It takes a certain amount of time to complete the opening or closing action, so it can be adjusted. Compare withstand voltage impact. The solenoid valve is quick open and quick close, which is generally used in places with small flow and small pressure, requiring high switching frequency; The electric valve is on the contrary. The opening of the electric valve can be controlled, with the states of open, close, half open and half close. It can control the flow of the medium in the pipeline, but the solenoid valve can not meet this requirement.  
The three wire electric valve has three lines F/R/N, F represents the forward action (or open action) control line, R represents the reverse action (or close action) control line, and N represents the ground wire. Solenoid valve is a kind of electric valve; The magnetic field generated by the solenoid coil is used to pull the valve core, so as to change the on-off of the valve body. When the coil is powered off, the valve core will return by the pressure of the spring.
3、 What kinds of electric valves are available:
1. According to the valve position function, the electric valve can be divided into: switching electric valve and regulating electric valve;
2. According to the valve position, it can be divided into: electric ball valve and electric butterfly valve;
3. According to the shape of valve body, it can also be divided into: ordinary electric valve and micro electric valve, explosion-proof electric valve;
4. The electric valve is usually of on-off type and regulating type;
5. According to the wiring, there are three wire system and two wire system. Large diameter is mostly three wire system, and small diameter can be two wire system and three wire system.
 Explosion proof electric low temperature ball valve Yonglong valve
Explosion proof electric low temperature ball valve Yonglong valve
4、 Operating environment of electric valve:
In addition to pipeline parameters, special attention should be paid to the working environment conditions of electric valves, because the electric device in electric valves is an electromechanical device, and its working conditions are greatly affected by its working environment. Generally, the working environment of electric valves is as follows:
1. Indoor installation or outdoor use with protective measures;
2. Outdoor installation, with wind, sand, rain, sun and other erosion;
3. Environment with combustible gas, liquid or dust;
4. Environment in humid and dry tropics;
5. The medium temperature of the pipeline is above 480 ℃;
6. The ambient temperature is below - 20 ℃;
7. Vulnerable to flooding or immersion;
8. Environment with radioactive substance (radioactive substance test device);
9. Environment on ships or docks (with salt fog, mould and humidity);
10. Occasions with severe vibration;
11. Places prone to fire;  
For electric valves in the above environment, the structure, materials and protective measures of electric devices are different. Therefore, the corresponding valve electric device shall be selected according to the above working environment.
 Liquid ammonia electric emergency shut-off valve Shanghai Yonglong Valve Factory
Liquid ammonia electric emergency shut-off valve Shanghai Yonglong Valve Factory
5、 Functional requirements of electric valve:
According to the engineering control requirements, the control function of the electric valve is completed by the electric device. The purpose of using electric valve is to realize non manual electrical control or computer control by opening, closing and regulating the valve. At present, the use of electric devices is not only to save manpower. Since the functions and quality of products from different manufacturers vary greatly, the selection of electric devices and valves are equally important to the project.
The valve electric device is an indispensable equipment for realizing valve program control, automatic control and remote control. Its movement process can be controlled by the stroke, torque or axial thrust. Since the working characteristics and utilization rate of the valve electric actuator depend on the type of valve, the working specification of the actuator and the position of the valve on the pipeline or equipment, the correct selection of the valve electric actuator is critical to prevent overload (the working torque is higher than the control torque).
6、 Attention shall be paid to the following points when selecting electric valves:
1. Operating torque The operating torque is the most important parameter for selecting the electric device of the valve. The output torque of the electric device should be 1.2~1.5 times of the maximum operating torque of the valve.
2. There are two main engine structures for operating the thrust valve electric device: one is to output torque directly without a thrust disc; The other is to configure a thrust disc, and the output torque is converted into output thrust through the stem nut in the thrust disc.
3. The number of turns of the output shaft of the valve electric device The number of turns of the output shaft of the valve electric device is related to the nominal diameter of the valve, the screw pitch of the valve stem, and the number of thread heads, which should be calculated as M = H / ZS (M is the total number of turns that the electric device should meet, H is the opening height of the valve, S is the screw pitch of the valve stem drive thread, and Z is the number of thread heads of the valve stem).
4. For multi turn rising stem valves, if the maximum valve stem diameter allowed by the electric device cannot pass through the valve stem of the valve, it cannot be assembled into an electric valve. Therefore, the inner diameter of the hollow output shaft of the electric device must be greater than the outer diameter of the stem of the rising stem valve. For some rotary valves and non rising stem valves in multi rotary valves, although the passage of the valve stem diameter is not considered, the valve stem diameter and the size of the keyway should also be fully considered when selecting, so that they can work normally after assembly.
5. If the opening and closing speed of the output speed valve is too fast, water hammer is likely to occur. Therefore, proper opening and closing speed shall be selected according to different service conditions.
6. The electric device of the valve has its special requirements, that is, it must be able to limit the torque or axial force. Usually, the valve electric device adopts the coupling that limits the torque. When the specification of the electric device is determined, its control torque is also determined.
Emergency stop valve, ammonia stop valve, liquid ammonia stop valve, pneumatic emergency stop valve, hydraulic emergency stop valve, gas emergency stop valve, low temperature stop valve, electric ball valve, pneumatic ball valve - Shanghai Yonglong Valve Factory
Source of the article: Sound of valves Valve ring

 Online Service