Butterfly valve with limit switch, butterfly valve with signal feedback, butterfly valve with transmitter
Product Overview:
The combination of wafer type butterfly valve and travel switch (signal feedback) is called signal butterfly valve. The signal butterfly valve is often used in fire protection system, tap water system, sewage system and other pipeline systems that need to display the valve switch status. The signal manual butterfly valve is made of nodular cast iron, carbon steel, stainless steel, fluorine lining and rubber lining. It can be selected according to different materials and sealing structures and used in the pipeline of petroleum, chemical, food, medicine, paper making, water and electricity, ships, water supply and drainage, smelting, energy and other systems. The signal fluorine lined butterfly valve is used as a regulating and throttling device on a variety of corrosive and non corrosive gas, liquid, semi fluid and solid powder pipelines and containers.
XD371X-16Q signal manual butterfly valve
Product features:
1. It is small and light, easy to disassemble and repair, and can be installed at any position.
2. The butterfly valve with signal feedback is simple and compact in structure, and can be opened and closed quickly by 90 ° rotation.
3. The operating torque of the butterfly valve with the transmitter is small, labor-saving and light.
4. Complete sealing is achieved, and the gas test leakage is zero.
5. The butterfly valve with travel switch can be made of different parts and materials, which can be applied to a variety of media.
6. The flow characteristics tend to be straight, and the regulation performance is good.
7. The number of opening and closing tests is up to 10000 times, and the service life is long.
8. All pipelines that use gate valves, ball valves, globe valves, plug valves, rubber hose valves and diaphragm valves, especially in high-rise building fire protection systems and pipeline systems that need to display the valve switch status, can be replaced by butterfly valves with limit switches.
working principle:
The signal butterfly valve is equipped with a signal turbine butterfly valve and a signal handle butterfly valve. Two microswitches in the open and close directions are set in the transmission device box, which act respectively when the valve is fully open and closed, and connect the "valve on" and "valve off" indicator light sources in the control room to accurately display the valve switch status. A closing microswitch is set in the transmission device box (the full closing position of the butterfly plate is 0 °). When the butterfly plate is in the position of 0~40 °, the microswitch is supported to output the valve closing signal. When the butterfly plate is in the position of 40 °~90 °, another pair of normally closed valves can output the valve opening signal. The cam of the press contact microswitch can be adjusted to display the different positions of the butterfly plate.
XD371X-16Q signal turbine butterfly valve
Adjustment and wiring method of worm gear transmission device:
1. Open the cover of the electrical switch box, connect the core wire of the cable to the corresponding terminal according to the electrical control requirements, seal the cable inlet, and fix the cable at the same time to prevent damage to the cable wiring when the external force affects.
2. When the valve is in the "fully closed" position, turn the lower closing cam clockwise, so that the cam just touches the microswitch (you can hear a click), and then tighten the screw on the cam to fix the cam.
3. When the valve is in the "full open" position, turn the upper open cam counterclockwise and adjust the open cam in the same way as above.
4. Adjust the limit screw. When the valve is in the "fully closed" or "fully open" position, the limit screw should not be just against the limit plane of the worm gear, but should have a certain clearance, and then tighten the lock nut on the limit screw.
5. Cover the electrical switch box cover. When the valve is in the "fully closed" position, make the pointer of the opening indicator point to the "0" scale on the dial, and tighten the screws to fix the pointer.
Related names: butterfly valve with limit switch, butterfly valve with signal feedback, butterfly valve with back transmitter, butterfly valve with travel switch