Collection
zero Useful+1
zero

Electronic eyepiece

A photoelectric microscope conversion device specially developed for microscope imaging
Electronic eyepiece It is a photoelectric microscope conversion device specially developed for microscope imaging. It can be easily applied to any standard Biological microscope Stereo microscope and Telescope tube Medium. Thus, it brings great rapidity and convenience to observation, teaching and scientific research. Common image sensors include CCD And CMOS. The difference is CCD image sensor Provide better quality, and CMOS image sensor Better performance in terms of battery life and low cost
Chinese name
Electronic eyepiece
Alias
Digital eyepiece
Introduction
A specially developed photoelectric micro conversion device
Features
Low cost and complete functions

definition

Announce
edit
KoPa electronic eyepiece
Microscope electronic eyepiece, also known as digital eyepiece, is specially designed for General optical microscope Developed and designed for image digitization. It has the characteristics of simple installation, strong versatility, low use cost, complete functions, simple and easy to use. Installation only requires two steps: 1. Remove the original microscope eyepiece; 2. Insert the electronic eyepiece to replace the original eyepiece. The full name of CMOS is Complementary metal oxide Complex Metal Oxide Semiconductor

advantage

Announce
edit
The image under the microscope can be transmitted to the computer through USB cable for real-time display, and the frozen image, video recording, measuring length, angle, radian, rectangular area and perimeter, irregular figure area and perimeter, cell counting, color segmentation, pseudo color restoration, virtual 3D, image edge recognition Fourier transformation Light spot measurement and some PS image processing functions. It can meet most professional applications.
Strong compatibility, can be replaced and upgraded at any time according to the change of use
Another advantage of electronic eyepiece is that it is a relatively independent device, different from the built-in camera system, with more flexibility and operability. When your application direction changes or requirements increase, you can upgrade the electronic eyepiece at any time without changing your microscope, so that your equipment will never be outdated, improve utilization and save money. When your laboratory has several different microscopes that need to collect digital images, you can also use the same electronic eyepiece to complete the image collection. Just change the electronic eyepiece to the microscope you are using. It is very convenient, and it is operated on the same computer that you are accustomed to using. It does not need to change the operating environment, which is more convenient and efficient.

application

Announce
edit
Application interface
Suitable for teachers' teaching and equipment Digital laboratory , medical research, industrial production (PCB circuit board inspection, IC quality control) medical care (Pathological section observation), food (microbial colony observation and counting), scientific research, education (teaching, demonstration, academic exchange), public security (seal verification, warhead detection) and other fields.

choice

Announce
edit
Selection of electronic eyepiece
For image products, the quality and performance are reflected in many aspects. The emphasis varies according to the use occasion and purpose. The key is to select a product that is cost-effective and suitable for your own use. We provide you with professional technical guidance and pre-sales consultation to help you make better use of each function of the product.
The following points are very important to choose a cost-effective and practical microscope camera product:
1. Grade category of image sensor
2. Performance of image processor DSP (color engine)
3. Optical structure characteristics
4. Supported image interface universality
5. Ease of use of software operation
6. After sales technical support
about Digital video For products, Image sensor It is an important component, and its type, size, and quality level are the basis of imaging effect. DSP color processing engine is the most critical factor to determine the image quality of the camera, and it is a parameter that is not widely understood but often ignored. It contains multiple processing of hardware and software, and is the core of perfect image reproduction. In addition, optical performance matching is also the key to image quality Optical glass lens High quality filters and lenses of specific wavebands have optical dust-proof design. Since the imaging focus plane is not on the top lens surface, a small amount of dust attached to the lens in use will not affect its imaging quality. The software and driver support Twain and Direct Show, the two most common standard image transmission interfaces in the world at present. The software has a friendly operation interface and can be selected from pure simplified Chinese and English versions. All of our image products enjoy a three-year warranty period. If you have any questions in use, you can contact our technical personnel and obtain professional guidance through online consultation, FAQ, email, telephone and other ways. Help you solve various application and use problems.

Specifications

Announce
edit
The optical interface of the electronic eyepiece that is widely used is the size of the international standard eyepiece, which is suitable for all kinds of biological microscopes with an inner diameter of 23.2mm, 30.0mm or 30.5mm Stereo microscope metallurgical microscope fluorescence microscope Polarizing microscope , melting point tester, hardness tester and other optical equipment. There is also a special model of C-Mount interface, which can be used on the standard C interface.
High quality digital eyepiece optical part adopts high transmittance and high quality optical glass Made of, greatly improving the performance of resin lens products. The assembly workshop is required to be equipped with thousand level dust-free and ultra-high voltage electrostatic dust removal equipment, and a new dust-proof structure is adopted to ensure the high-quality effect of each product.
With CFS multi focus convergence optical system (special configuration) -- optical dust-proof lens -- anti glare lens

parameter

Announce
edit
Technical parameters of general electronic eyepiece
data output
USB 2.0, Support Direct Show&Twain
sensor
1/2 inch large array color sensor
Ultra fine color engine
Dynamic effective pixels 5 million
Horizontal resolution
>2000 TV Lines
data type
True color 24Bit R × G × B × 8
Effective resolution
2592 × 1944 (hardware)
Frame rate
7fps @ 2592 × 1944 Maximum speed up to 30fps
Image capture
High speed preview and "static" capture, instant capture, video stream recording
Video format
2592×1944 / 1280×960 / 800×600 / 640×480
spectral response
400-650nm (IR-Cut added)
sensitivity
1.2v/lux-sec @550nm
dynamic range
>68dB
Driver
Direct Show and Twain
Power Supply
USB 2.0 output DC 5V/350 mA
Image control
White balance: automatic white balance+manual R-G-B adjustment
Exposure: auto exposure/target value setting/exposure time control/gain setting
Color: color black white mode switch/gamma/saturation/contrast
Auxiliary settings: image horizontal inversion/vertical inversion
Light source frequency: 50Hz/60Hz switching
Frame rate: low speed/high speed

Main conditions

Announce
edit
System requirements for general electronic eyepieces
★ Intel Pentium 2.0GHz CPU (Dual core 2.8GHz or higher configuration is recommended)
★ Windows 2000 / XP(SP2-SP3) / Vista
★ DirectX 9.0 or later
★ 1GB memory or higher
★ CD-ROM drive
★ 32 bit graphics card
★ 21 "display or larger
★ High speed USB 2.0 port

be careful

Announce
edit
Electronic eyepiece is a precision photoelectric instrument. During storage, transportation and use, please do not vibrate violently, drop, immerse in water or use in high temperature and humidity environment. During installation, do not stain, contaminate or scratch the CCD or lens surface, and do not pull or bend the signal connection wire with force.
After use, please cut off the power supply in time to prevent long-term standby state and accelerate the aging of equipment components.
The production and assembly of electronic eyepiece shall be completed in a dust-free condition. Please do not open the back cover and field mirror of this equipment at will. There are no user maintainable parts inside to avoid damage to internal components.