Thermocouple circuit

Closed circuit with temperature difference between two points
Thermocouple Also called Thermoelectric couple It is the first thermoelectric detector. Its working principle is thermoelectric effect Seebeck effect Made Temperature sensor In a circuit, there is a temperature difference between two points Closed circuit It is called thermocouple circuit.
In the circuit, the closed circuit with temperature difference between two points is called thermocouple circuit.
Chinese name
Thermocouple circuit
Foreign name
Electrical circuit of thermocouple
Field
Physical electricity
Pinyin
rè diàn ǒu diàn lù
Also called
Thermocouple circuit
Advantages
High precision, wide range, simple and convenient

principle

Announce
edit
Its working principle is Thermoelectric effect For example, a junction made of two different conductor materials can be generated at the junction emf The magnitude and direction of this electromotive force is related to the properties of two different conductor materials at the contact and the temperature difference at the two contacts. If these two different conductor materials are connected into a circuit, current will be generated in the circuit when the temperature at the two joints is different. This phenomenon is called thermoelectric effect or Seebeck effect constitute Thermoelectric couple The material of can be either metal or semiconductor Structurally, it can be a line or strip entity, or it can be used Vacuum deposition technology or Photolithography Made of film. Solid thermocouple is mostly used for temperature measurement, and thin film thermocouple Thermoelectric The stack (composed of many thermocouples in series) is often used to measure radiation, for example, to calibrate various light sources, measure various radiation quantities Infrared spectrophotometer or Infrared spectrometer Radiation receiving element, etc. [1]

Specific operation

Announce
edit
Thermocouples can be used to prevent the main gas valve from opening, or to close the main valve when the signal flame goes out. The hot end of the thermocouple is installed in the signal flame. Thermocouples can produce small currents. When the temperature controller contact is closed, the current generated by the thermocouple will open the pilot solenoid valve on the gas supply pipe. The solenoid pilot valve operates the main gas valve. In case of open circuit, the thermocouple generates a voltage of 30mV (1v is equal to 10130mV). The reading is 2mV higher or lower than this value, indicating that the thermocouple is damaged. The solenoid pilot valve shall operate at least 7mV. If the heating flame at the hot end goes out, as long as the solenoid coil works normally, it will lose its magnetic force within one minute. (However, some standards allow the system to be shut down for three minutes in domestic and small commercial units). It is better to use aluminum tube as the gas connection pipe of the signal flame (there will be peeling reaction in the copper tube). Electrolysis of aluminum tube must be prevented (usually with outer plastic protective sleeve). If the signal flame is too high (with adjusting screw), the thermocouple may be overheated and damaged. If the main burner flame contacts the thermocouple, it will be damaged. [2]

application

Announce
edit
Thermocouple circuit can generally measure temperature, and can also be used as sensor Use. When the outside temperature changes, some control can be carried out. For example, control the water temperature, air temperature Etc.

advantage

Announce
edit
Thermocouple is one of the most commonly used temperature detection elements in industry. The working principle of thermocouple is based on Seeback effect, that is, two ends of conductors with different components are connected into a loop. If the temperature of two connection ends is different, it will be generated in the loop Thermal current The physical phenomenon of. Its advantages are:
① High measurement accuracy. Since the thermocouple is in direct contact with the measured object, it is not affected by the intermediate medium.
② Wide measuring range. Commonly used thermocouples can be continuously measured from - 50~+1600 ℃. Some special thermocouples can be measured to - 269 ℃ at least (such as gold iron nickel chromium) and+2800 ℃ at most (such as tungsten rhenium).
③ Simple structure and convenient use. Thermocouple is usually composed of two different types of metal wires, and is not limited by size and start. It is very convenient to use because it has a protective sleeve outside. [3]