Multistage centrifugal pump

Tools for casting iron by centrifugal force
multistage centrifugal pump It is the combination of more than two centrifugal pumps with the same function, and the fluid channel structure is shown in the first stage medium Pressure relief port It is connected with the inlet of the second stage, and the medium pressure relief port of the second stage is connected with the inlet of the third stage. Such a mechanism in series forms a multistage centrifugal pump.
The significance of multistage centrifugal pump is to increase the set pressure.
Chinese name
Multistage centrifugal pump
Foreign name
Multistage centrifugal pump
Industry
Machinery manufacturing
Material
cast iron
Model
D
Performance
High head
working principle
Effect of centrifugal force

Product features

Announce
edit
1. The multi-stage centrifugal pump is a vertical structure with a small floor area. The center of gravity of the pump coincides with the center of the pump foot, so it runs stably, has small vibration and long service life.
2. The multi-stage centrifugal pump has the same caliber and is on the same horizontal centerline. It can be directly installed at any part of the pipeline without changing the pipeline structure, which is very convenient for installation.
3. Motor external Rain cover It can be directly placed outdoors for use without the need to build a pump room, greatly saving Infrastructure investment
Structural drawing of multistage centrifugal pump
4. The lift of multistage centrifugal pump can meet different requirements by changing the pump stages (number of impellers), so it has a wide range of applications.  5、 Shaft seal use Hard alloy Mechanical seal , reliable sealing, no leakage, Mechanical loss Small.
6. High efficiency, energy saving and beautiful appearance.
7. Note: Internal casting with diameter above 50 is formed.

Scope of application

Announce
edit
Multistage centrifugal pump, which adopts the high efficiency and energy saving recommended by the state hydraulic model With high efficiency and energy saving, wide performance range Operation safety Stable, low noise, long life, easy installation and maintenance, etc; By changing the material and sealing form of the pump and adding a cooling system, hot water, oil, corrosive and abrasive media can be transported.
Type D pump is used to transport clean water or physical materials that do not contain solid particles and whose temperature is not higher than 80 ℃ chemical property Liquid similar to clean water, suitable for mines and cities Water supply and drainage engineering use.
DG type pump is used to transport clean water without solid particles and with a temperature not higher than 105 ℃ or liquid with physical and chemical properties similar to clean water Boiler feed water Or medium for transporting hot water or similar hot water.
MD pump is used to transport neutral materials with solid particle content no more than 1.5% Mineral water (particle size is less than 0.5 millimeter )And other similar sewage, the temperature of the conveyed medium is not higher than 80 ℃, suitable for steel plants Mine drainage , sewage transportation, etc.
The delivery temperature of DF pump is - 20 ℃~105 ℃, without solid particles and corrosive liquid.
Horizontal multistage centrifugal pump
DY pump is used to transport oil and petroleum products
Inlet of above pumps Allowable pressure Not more than 0.6MPa.
Multistage centrifugal pump Structure diagram
Structural drawing of multistage centrifugal pump

performance parameter

Announce
edit
model
series
flow
(m3/h)
lift
(M)
speed
(r/min)
Motor power
(kw)
efficiency
(%)
NPSH required
(NPSH)
weight
25GDL2-12
three
one point four
two
two point four
thirty-six
two thousand and nine hundred
one point one
twenty-three
thirty
thirty-two
two point nine
fifty-eight
four
forty-eight
one point one
two point nine
sixty-two
five
sixty
two
two point nine
sixty-eight
six
seventy-two
two
two point nine
seventy-two
seven
eighty-four
two
two point nine
seventy-eight
eight
ninety-six
two point two
two point nine
eighty-two
nine
one hundred and eight
two
two point nine
eighty-six
ten
one hundred and twenty
three
two point nine
ninety-eight
eleven
one hundred and thirty-two
three
two point nine
one hundred and two
twelve
one hundred and forty-four
three
two point nine
-
thirteen
one hundred and fifty-six
four
two point nine
fourteen
one hundred and sixty-eight
four
two point nine
fifteen
one hundred and eighty
four
two point nine
25GDL4-11
three
two point eight
four
four point eight
thirty-three
two thousand and nine hundred
one point one
thirty-two
forty-two
forty-three
two point nine
fifty-eight
four
forty-four
one point five
two point nine
sixty-five
five
fifty-five
two point two
two point nine
seventy-two
six
sixty-six
two point two
two point nine
seventy-six
seven
seventy-seven
three
two point nine
eighty-six
eight
eighty-eight
three
two point nine
ninety
nine
ninety-nine
three
two point nine
ninety-four
ten
one hundred and ten
four
two point nine
one hundred and ten
eleven
one hundred and twenty-one
four
two point nine
one hundred and fourteen
twelve
one hundred and thirty-two
four
two point nine
-
thirteen
one hundred and forty-three
four
two point nine
fourteen
one hundred and fifty-four
five point five
two point nine
fifteen
one hundred and sixty-five
five point five
two point nine
model
series
flow
(m3/h)
lift
(M)
speed
(r/min)
Motor power
(kw)
efficiency
(%)
NPSH required
(NPSH)
weight
40GDL6-12
three
four point two
six
seven point two
thirty-six
two thousand and nine hundred
one point five
forty-three
fifty-two
fifty
two point nine
seventy-two
four
forty-eight
two point two
two point nine
seventy-eight
five
sixty
two point two
two point nine
eighty-two
six
seventy-two
three
two point nine
ninety-two
seven
eighty-four
three
two point nine
ninety-six
eight
ninety-six
four
two point nine
one hundred and twelve
nine
one hundred and eight
four
two point nine
one hundred and sixteen
ten
one hundred and twenty
four
two point nine
one hundred and twenty
eleven
one hundred and thirty-two
five point five
two point nine
one hundred and forty
twelve
one hundred and forty-four
five point five
two point nine
-
thirteen
one hundred and fifty-six
seven point five
two point nine
fourteen
one hundred and sixty-eight
seven point five
two point nine
fifteen
one hundred and eighty
seven point five
two point nine
50GDL12-15
two
eight point four
twelve
fourteen point four
thirty
two thousand and nine hundred
two point two
forty-nine
fifty-seven
fifty-five
three point five
one hundred and thirteen
three
forty-five
three
three point five
one hundred and twenty-nine
four
sixty
four
three point five
one hundred and forty-nine
five
seventy-five
five point five
three point five
one hundred and eighty-one
six
ninety
five point five
three point five
one hundred and ninety
seven
one hundred and five
seven point five
three point five
two hundred and four
eight
one hundred and twenty
seven point five
three point five
two hundred and twelve
nine
one hundred and thirty-five
eleven
three point five
two hundred and sixty-five
ten
one hundred and fifty
eleven
three point five
two hundred and seventy-three
50GDL18-15
two
twelve point six
eighteen
twenty-one point six
thirty
two thousand and nine hundred
three
fifty-four
sixty-three
sixty-two
four
one hundred and twenty-two
three
forty-five
four
four
one hundred and forty-two
four
sixty
five point five
four
one hundred and seventy-five
five
seventy-five
seven point five
four
one hundred and eighty-nine
six
ninety
seven point five
four
one hundred and ninety-eight
seven
one hundred and five
eleven
four
two hundred and fifty-two
eight
one hundred and twenty
eleven
four
two hundred and sixty-one
nine
one hundred and thirty-five
fifteen
four
two hundred and eighty
ten
one hundred and fifty
fifteen
four
two hundred and eighty-nine

matters needing attention

Announce
edit
1. Pre startup inspection of multistage centrifugal pump
Whether the name, model, main performance and filling quantity of lubricating oil meet the requirements Technical documents Requirements; Bearing lubrication system , sealing system and Cooling system Whether it is in good condition, and whether the oil and water paths of the bearing are unblocked;
Turn the rotor of the pump for 1-2 revolutions, and check whether there is friction or seizure of the rotor;
stay coupling Nearby or belt Protective device Whether there are sundries hindering rotation;
Pump Bearing pedestal Motor foundation Foundation bolt Whether it is loose;
Multistage centrifugal pump
The valve or accessory device of the pump working system shall be at the position with the minimum load when the pump is running, and the outlet shall be closed Regulating valve
Start the multistage centrifugal pump and check whether the impeller rotation is consistent with the design rotation. If not, the impeller must be completely stopped and the motor wiring must be adjusted before starting again.
2. Multi stage centrifugal pump water filling
Before starting the pump, the pump casing and suction pipe must be filled with water, because the vacuum of multistage centrifugal pump suction cannot be formed and maintained in the presence of air.
3. Multi stage centrifugal pump warming
Pumps for delivering high-temperature liquids, such as those in power plants Boiler feed pump Warm up the pump before starting the multistage centrifugal pump. that is because Feed pump During startup, high temperature feed water flows through the pump, making the temperature of the pump body rise quickly from normal temperature to 100~200 ℃, which will cause the temperature difference between the inside and outside of the pump and between various components. Without sufficient heat transfer time and appropriate measures to control the temperature rise, uneven expansion of the pump will occur everywhere, causing deformation, wear, vibration and bearing axle seizure accidents of various parts of the pump body.

maintain

Announce
edit

Cleaning items

1、 Scrape off the inner and outer surfaces of the impeller and Sealing ring The scale and rust accumulated in the bearing and other places shall be cleaned and blown with water or compressed air.
2、 Clean the deposits on the joint surfaces of the shell Oil stain And rust.
3、 Clean the water seal pipe and check whether the pipe is unblocked.
4、 Cleaning bearing bush And bearing, remove oil dirt, and Cleaning oil Ring and oil level gauge, etc. Ball bearing Use gasoline for cleaning.
5、 Parts and components not to be assembled temporarily shall be protected with oil after cleaning.

Basic cleaning principles

1. Ensure that the requirements for cleanliness of parts are met. During repair, different parts have different requirements for cleanliness. In assembly, the cleaning requirements of mating parts are higher than those of non mating parts, and that of moving mating parts are higher than Static fit Precision parts are higher than non precision parts. For the surfaces of sprayed, plated and bonded workpieces, the cleaning requirements are very high. Different cleaning agents and cleaning methods must be adopted according to different requirements
Methods to ensure the required cleaning quality.
2. Prevent corrosion of parts, and do not allow any degree of corrosion of precision parts. When the parts need to be parked for a period of time after cleaning, the antirust ability of the cleaning solution or other antirust measures should be considered.
3. Ensure operation safety, and prevent fire or poisoning to human body and environmental pollution.