home page  >  Product supply  >  Housewear & Furnishings  >  Household Electric Appliances  >  Other electrical appliances >Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating
  •  Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating

Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating

Price

Electric discussion

  • Minimum order quantity: 1 set
  • Location: Changzhou, Jiangsu
  • Price: electricity
  • Total supply: 9999 sets
  • Delivery period: 15 days
  • Release time: April 26, 2024 16:23:30

Zou Ping: (Please tell me when you contact me“ Building materials network See the information, there will be a discount! Thank you!)

Warm reminder: Consumers are requested to take epidemic prevention measures for international packages. The goods need three licenses and one report for imported goods (supplier's license, entry quarantine certificate, preventive disinfection certificate and NCV nucleic acid test report)

Detailed description

Full DC variable frequency heating pump Cooling and heating machine series
Unit performance parameter table
Product model RF8IADC RF12IADC RF16IADC RF18IADC
Number of pieces 3HP 5HP 6HP 8HP
Applicable voltage/frequency 220V/1PH/50HZ
Rated heating (7/6 ℃) Rated heat 9.0KW 15.0KW 18.0KW 24.0KW
Rated heating input power 2.62KW 4.27KW 5.17KW 6.92KW
Rated heating input current 11.91A 19.40A 23.51A 31.44A
Rated heating COP three point four four three point five one three point four eight three point four seven
Nominal heating (- 12/- 14 ℃) Nominal heating capacity 6.0KW 10.0KW 12.0KW 16.0KW
Nominal heating input power 2.61KW 4.31KW 5.20KW 6.81KW
Nominal heating input current 11.86A 19.60A 23.7A 30.9 Advanced
Nominal heating COP two point three zero two point three two two point three one two point three five
Rated refrigeration (35/24 ℃) Rated cooling capacity 8.3KW 12.0KW 15.5KW 18.0KW
Rated cooling input power 2.76KW 3.97KW 5.03KW 8.18KW
Rated cooling input current 12.53A 18.01A 22.90A 37.20A
Rated cold EER three point zero one three point zero two three point zero eight three point zero five
Comprehensive energy efficiency coefficient IPLV (H) two point seven six two point eight zero two point eight five two point eight seven
Zu da input power 4.2KW 5.5KW 6.6KW 8.3KW
Zu da input current 20.0A 25.0A 30.0A 38.0A
Rated water flow >1.6m3/h >1.72m3/h >2.10m3/h >2.76m3/h
Water side pressure loss 22.0Kpa 38.5Kpa 41.0Kpa 59.5Kpa
Access Water pipe size DN25, brass internal thread
Noise value ≦56.0dB 60.0dB ≦61.0dB 67.0dB
Overall dimensions of unit 970*350*935mm 1050*430*1450mm 1050*430*1450mm 1400*480*1410mm
Unit weight 72kg/80kg 125kg/132kg 130kg/138kg 175kg/188kg
Applicable heating temperature range 20℃~60℃
Applicable refrigeration temperature range 5℃~20℃
Operating temperature range =[Inpesore door User. xls] Third party website$ B:$B
remarks:
1. Rated refrigeration condition: outdoor environment dry bulb 35 ℃/wet bulb 24 ℃, inlet water temperature 12 ℃, outlet water temperature 7 ℃.
2. Rated heating condition: outdoor environment dry bulb 7 ℃/wet bulb 6 ℃, inlet water temperature 40 ℃, outlet water temperature 45 ℃.
3. Nominal heating condition: outdoor environment dry bulb - 12 ℃/wet bulb - 14 ℃, outlet water temperature 41 ℃.
4. Unit parameters are subject to change without notice due to product improvement. Please refer to the unit nameplate.

I want to comment

Negative comments such as slander, malicious attack, unsubstantiated and non positive energy will be deleted by the administrator. Your comments may be of high reference value to others.

Related comments

Well received
0%
Neutral comment
0%
negative comment
0%
/ Number of records: 98   home page previous page next page Last

Disclaimer: The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legality of the content are the responsibility of the publishing enterprise. www.chinabuildingmaterials. com does not assume any guarantee responsibility for this. In order to protect your interests, we suggest you choose the building materials link member of China Building Materials Network. Friendly reminder: New and old users are requested to strengthen the screening of the authenticity of information and the identity and qualification of its publisher to avoid unnecessary disputes and losses!

Supply Classification

Jiangsu Yingposol New Energy Co., Ltd

Ordinary members
Certified
  • Enterprise type:

    Others

  • Business model:

    Production and processing

  • Honors and qualifications:

    0 items

  • Main business:

    Air source heat pump, ground source heat pump, air conditioning heat pump, solar water heater, solar collector

  • Address:

    No. 5 Shengda Road, Airport Industrial Park, Luoxi Town, Xinbei District, Changzhou, Jiangsu

I want to join

Online inquiry
  • Jiangsu Yingposol New Energy Co., Ltd

  • Full DC variable frequency heat pump chiller/heater _ North air energy heat pump heating