home page  >  Product supply  >  Fine chemical industry  >  coating  >  Fire retardant coating >Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating
  •  Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating

Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating

Price

MOQ

1.00 yuan/kg

1 kg

  • Minimum order quantity: 1kg
  • Location: Cangzhou, Hebei
  • Price: electricity
  • Total supply: 57578 kg
  • Delivery period: 3 days
  • Release time: 2024-05-18 00:01:36

(When contacting me, please specify that the Building materials network See, there will be a discount! Thank you!)

Warm reminder: Consumers are requested to take epidemic prevention measures for international packages. The goods need three licenses and one report for imported goods (supplier's license, entry quarantine certificate, preventive disinfection certificate and NCV nucleic acid test report)

Detailed description

  • Color:

    brown

  • Brand:

    Yinuo Fire Protection

  • Glossiness:

    two

  • Water resistance:

    fifteen

  • Acid resistance:

    fifteen

  • Constructability:

    Class I fire protection

  • Maximum drying time:

    2 hours

  • Minimum total solids content:

    100 %

  • Painting area per kg (twice):

    50 ㎡

  • Net weight of single piece:

    25 kg

  • Purpose:

    Steel structure fireproof coating

  • Package specification:

    Bagged

  • Type:

    Steel structure fireproof coating

GT-NSF3.0 thick steel structure Fire retardant coating Thickness requirements

GT-NSF3.0 thick steel structure fire protection coating The thickness is in accordance with the requirements of GB149070-2018 fire retardant coating specification. The coating thickness needs to be more than 15mm. The fire resistance of this product is limited to 3.0h. It can be used for fire protection of ordinary steel structures, indoor plants, warehouses, production workshops and multi-storey buildings, and can be used for Class I fire protection as required by the building fire protection design code.

Fire and heat insulation principle of non expansive fire retardant coating:

Coated on steel members Non expansive fireproof coating The principle of fire protection and heat insulation is that the volume of the coating basically does not change when the fireproof coating is exposed to fire, but the thermal conductivity of the coating is very low, which delays the speed of heat transfer to the protected base material. The coating of the fireproof coating itself is incombustible, acts as a barrier and prevents thermal radiation on the steel members, and avoids the direct attack of flame and temperature on the steel members . In addition, some components in the coating react with each other when encountering fire to generate incombustible gas, which is an endothermic reaction and also consumes a lot of heat, which is conducive to reducing the system temperature, so the fire prevention effect is significant, and it can provide fire and heat insulation protection for steel . In addition, this kind of fireproof coating for steel structure changes to form a glaze protective layer when it is exposed to fire, which can isolate oxygen, so that oxygen can not be contacted by the combustible substrate that can not be protected, thus avoiding or reducing combustion reaction . Thick coating fire retardant coating It is a modern good heat insulation and fire retardant coating for steel structure

GB14907-2002.   

S/N

project

Technical indicators

Measured results

one

stay container Status in

No caking, stirred evenly, thick fluid

Uniform thick fluid, no caking

two

Drying time (surface drying), h

≤24

sixteen

three

Initial drying crack resistance

Generally, there should be no cracks, 1-3 cracks are allowed, and the width should be ≤ 1mm.

No crack

four

Bond strength, Mpa

≥0.04

zero point two

five

Compressive strength, Mpa

≥0.3

zero point six

six

Dry density, (kg/m3)

≤500

four hundred and sixty-one

seven

Water resistance, h

The coating shall be free of delamination, foaming and falling off for ≥ 24h.

qualified

eight

Cold and hot cycle resistance (times)

≥ 15 times of coating shall be free of cracking, peeling and blistering.

qualified

nine

Fire resistance

Coating thickness, mm

25±2

twenty-five

Fire resistance limit, h

≥2

three

  •  Business license

    Business license

I want to comment

Negative comments such as slander, malicious attack, unsubstantiated and non positive energy will be deleted by the administrator. Your comments may be of high reference value to others.

Related comments

Well received
0%
Neutral comment
0%
negative comment
0%
    / Number of records: 98   home page previous page next page Last

    Disclaimer: The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legality of the content are the responsibility of the publishing enterprise. www.chinabuildingmaterials. com does not assume any guarantee responsibility for this. In order to protect your interests, we suggest you choose the building materials link member of China Building Materials Network. Friendly reminder: New and old users are requested to strengthen the screening of the authenticity of information and the identity and qualification of its publisher to avoid unnecessary disputes and losses!

    Risk warning: Entrepreneurship is risky and investment should be cautious. Fight against investment fraud and create a platform of integrity. Right protection report: 400-88-59137.

    Cangzhou Yinuo Fireproof Materials Co., Ltd

    Building Materials General

    seven year

    Certified
    • Enterprise type:

      Building materials enterprises

    • Business model:

      Production and processing

    • Honors and qualifications:

      1 item

    • Main business:

      Steel structure fireproof coating, cable fireproof coating, fireproof bag, fireproof mud, fireproof board, fireproof module, fireproof sealant, fireproof cloth

    • Address:

      Hebei Cangzhou Hejian Wofo Hall

    I want to join

     Personal WeChat
    Online inquiry
    • Cangzhou Yinuo Fireproof Materials Co., Ltd

    • Thickness requirements of GT-NSF3.0 thick steel structure fireproof coating