Flame retardant and fire-resistant Control cable ZAN-KYJVP armored red shield
model |
Product name |
NH-KVV
|
Flame retardant polychloride ethylene Insulation and sheath fire resistance control Cable |
NH-KVVP
|
Flame retardant PVC insulated and sheathed copper wire braided shield fire-resistant control cable |
NH-KVVP2 |
Flame retardant PVC insulated and sheathed copper tape wrapped shielded fire-resistant control cable |
NH-KFF
|
Fluoroplastic insulated and sheathed fire-resistant control cable |
NH-KFFP |
Fluoroplastic insulated and sheathed copper wire braided shield fire-resistant control cable |
NH-KFFP2 |
Fluoroplastic insulated and sheathed copper tape wrapped shielded fire-resistant control cable |
NH-KVDVD |
Low smoke and low halogen flame-retardant PVC insulated and sheathed fire-resistant control cable |
NH-KVDVDP |
Low smoke and low halogen flame-retardant PVC insulated and sheathed copper wire braided shield fire-resistant control cable |
NH-KVDVDP2 |
Low smoke and low halogen flame-retardant PVC insulated and sheathed copper wire braided shield fire-resistant control cable |
NH-KYDYD |
Low smoke halogen-free flame retardant polyolefin insulated and sheathed fire-resistant control cable |
NH-KYDYDP |
Low smoke halogen-free flame retardant polyolefin insulated and sheathed copper wire braided shield fire-resistant control cable |
NH-KYDYDP2 |
Low smoke halogen-free flame retardant polyolefin insulated and sheathed copper wire braided shield fire-resistant control cable |
NH-KYJV |
Cross linked polyethylene insulated flame-retardant PVC sheathed fire-resistant control cable |
NH-KYJVP |
Cross linked polyethylene insulated flame-retardant PVC sheathed copper wire braided shield fire-resistant control cable |
NH-KYJVP2 |
XLPE insulated flame-retardant PVC sheathed copper tape wrapped shield fire-resistant control cable |
Flame retardant and fire-resistant control cable ZAN-KYJVP armored red sheath product executive standard
Fire resistance characteristics meet the requirements of GB12666.6-90 (IEC331)
3: Use Properties
1. AC rated voltage: U0/U 0.6/1KV
2. High long-term working temperature: flame retardant PVC insulation and sheath 70 ℃ and 105 ℃
Fluoroplastic insulation and sheath 200 ℃ and 260 ℃
XLPE insulation 90 ℃
Low smoke halogen-free flame retardant polyolefin 70 ℃
Low smoke halogen-free flame retardant cross-linked polyolefin 90 ℃ and 120 ℃
3. Lower ambient temperature: flame-retardant PVC sheath: fixed laying - 40 ℃, non fixed laying - 15 ℃
Fluoroplastic insulation and sheath: fixed laying - 60 ℃; Non fixed laying - 20 ℃
4. Flame retardant and fire-resistant control cable ZAN-KYJVP armored red sheath fire resistance characteristics:
Comply with IEC331
|
Flame temperature 750 ℃, combustion time 3h, cooling time 12h, additional rated voltage, additional 3A current
|
Conform to GB12666.6 - Class A
|
Flame temperature 950-1000 ℃, combustion time 90min, additional rated voltage 3A current
|
Conform to GB12666.6-B
|
Flame temperature 750-800 ℃, combustion time 90min, additional rated voltage 3A current
|
5. Cable installation and laying temperature shall not be lower than 0 ℃
6. Recommended allowable bending radius for laying: no less than 6 times of the outer diameter of the cable for unarmoured cable
Armored cable shall not be less than 12 times of cable outer diameter
Fluoroplastic insulated and sheathed cable shall not be less than 8 times of the outer diameter of the cable
4: Basic model and name of flame-retardant and fire-resistant control cable ZAN-KYJVP armored red sheath
Table 1
model
|
Product name
|
NH-VV
|
Flame retardant PVC insulated and sheathed fire-resistant control cable
|
NH-FF
|
Fluoroplastic insulated and sheathed fire-resistant control cable
|
NH-VDVD
|
Low smoke and low halogen flame-retardant PVC insulated and sheathed fire-resistant control cable
|
NH-YDYD
|
Low smoke halogen-free flame retardant polyolefin insulated and sheathed fire-resistant control cable
|
Note: add 22 after the armored cable model
|
2. Fire resistant control cable
model
|
Product name
|
NH-KVV
|
Flame retardant PVC insulated and sheathed fire-resistant control cable
|
NH-KVVP
|
Flame retardant PVC insulated and sheathed copper wire braided shield fire-resistant control cable
|
NH-KVVP2
|
Flame retardant PVC insulated and sheathed copper tape wrapped shielded fire-resistant control cable
|
NH-KFF
|
Fluoroplastic insulated and sheathed fire-resistant control cable
|
NH-KFFP
|
Fluoroplastic insulated and sheathed copper wire braided shield fire-resistant control cable
|
NH-KFFP2
|
Fluoroplastic insulated and sheathed copper tape wrapped shielded fire-resistant control cable
|
NH-KVDVD
|
Low smoke and low halogen flame-retardant PVC insulated and sheathed fire-resistant control cable
|
NH-KVDVDP
|
Low smoke and low halogen flame-retardant PVC insulated and sheathed copper wire braided shield fire-resistant control cable
|
NH-KVDVDP2
|
Low smoke and low halogen flame-retardant PVC insulated and sheathed copper wire braided shield fire-resistant control cable
|
NH-KYDYD
|
Low smoke halogen-free flame retardant polyolefin insulated and sheathed fire-resistant control cable
|
NH-KYDYDP
|
Low smoke halogen-free flame retardant polyolefin insulated and sheathed copper wire braided shield fire-resistant control cable
|
NH-KYDYDP2
|
Low smoke halogen-free flame retardant polyolefin insulated and sheathed copper wire braided shield fire-resistant control cable
|
NH-KYJV
|
Cross linked polyethylene insulated flame-retardant PVC sheathed fire-resistant control cable
|
NH-KYJVP
|
Cross linked polyethylene insulated flame-retardant PVC sheathed copper wire braided shield fire-resistant control cable
|
NH-KYJVP2
|
XLPE insulated flame-retardant PVC sheathed copper tape wrapped shield fire-resistant control cable
|
Note: 22 is added after the armored cable model, and P2, P3 and other forms can be used for the shield type of soft structure cable.
|
5: Code name and meaning
project
|
Code
|
explain
|
Fire resistance characteristics
|
NH
|
Fire resistant cable A or B
|
Series code
|
K
|
Control cable
|
|
V
|
PVC, flame retardant PVC
|
Y
|
polyethylene
|
YD
|
Low smoke halogen-free polyolefin (YDJ low smoke halogen-free crosslinked polyolefin)
|
YJ
|
Cross linked polyethylene
|
F
|
Fluoroplastics are divided into 200 ℃ and 260 ℃
|
Jacket material
|
V
|
PVC, flame retardant PVC
|
F
|
Fluoroplastics are divided into 200 ℃ and 260 ℃
|
YD
|
Low smoke halogen-free polyolefin
|
Shielding material
|
P
|
Copper wire braided shield
|
P2
|
Copper tape wrapped shield
|
P3
|
Aluminum plastic wrapped shield
|
Armor material
|
twenty-two
|
Steel tape armored PVC sheath
|
thirty-two
|
Steel wire armored PVC sheath
|
Conductor structure
|
A
|
Single strand conductor
|
B
|
7 Stranded Conductors
|
R
|
Stranded conductor
|