Kunshan Zhoushi Muyakai Mechanical and Electrical Equipment Firm is specialized in polymer material composition analyzer, o-benzene 4P detector, o-benzene four item detector, domestic ROHS2.0 standard test instrument, Tianrui alloy grade analyzer ROHS2.0 ten item analyzer, handheld non methane total hydrocarbon detector, Tianrui insulation cup ROHS tester, handheld FID hydrogen flame VOC gas detectorResearch, development, production and sales of analytical testing instruments and software such as plating surface thickness gauge.
Qualification
Kunshan Zhoushi Muyakai Mechanical and Electrical Equipment FirmX-ray fluorescence spectrometer, ROHS environmental protection detector, gas phase mass spectrometer, handheld X-ray fluorescence spectrometer, alloy spectrum detector
collimator0.1mmOverall dimension576(W)*495(D)*545(H)mmDisplay modemicronsupply voltage220V±5Vmeasuring range Sulfur uranium
Plating thickness measurement has become an important link in processing industry and surface engineering quality detection, and is a necessary means for products to reach superior quality standards.In order to make the product * *, there are clear requirements for the thickness of plating in China's export commodities and foreign-related projects. The measurement methods of coating thickness mainly include wedge cutting method, optical sectioning method, electrolytic method, thickness difference measurement method, weighing method, X-ray fluorescence method, β - ray backscattering method, capacitance method, magnetic measurement method, eddy current measurement method, etc.Among these methods, * * are destructive tests, which are tedious and slow, and are mostly suitable for sampling inspection. The X-ray and β - ray methods are non-contact nondestructive measurement with a small measurement range. The X-ray method can measure thin coatings, double coatings and alloy coatings.The beta ray method is suitable for the measurement of coatings and substrates with atomic number greater than 3.The capacitance method is only used for measuring the thickness of the insulation coating of thin conductors. With the increasing progress of technology, especially after the introduction of microcomputer technology in recent years, the use of X-ray coating thickness gauge has made a step towards miniaturization, intelligence, multi-function, high-precision and practicality.The resolution of the measurement has reached 0.1 μ m, and the accuracy can reach 1%, which has been greatly improved.It has wide application range, wide measuring range, simple operation and * *. It is a thickness measuring instrument widely used in industry and scientific research. With the emergence of plastic and fully plastic automobiles in the automotive industry, the application of plastic electroplating is increasingly widespread. At home and abroad, electroplating has been widely carried out on the surface of (/butadiene/styrene) copolymer (ABS), polypropylene, polysulfone, polycarbonate, nylon and other materials, especially ABS plastic electroplating. The electroplating effect is zuihao.ABS plastic products plated with bright chrome have the characteristics of light texture and beautiful shape. The chrome layer has silver blue mirror luster, good reflective performance and decorative performance. It has the characteristics of "toughness, hardness and rigidity" when used in the manufacture of automobile lampshades. Short delivery time Quick installation Short maintenance cycle Long warranty period Personalized service maintenance cost Performance advantages Meet the test requirements of samples with different thicknesses and samples with irregular surfaces The hole collimator with a small diameter of 0.1mm can meet the requirements of small test points High precision platform can locate test points, and the repeated positioning accuracy is less than 0.005mm Height positioning laser is used to automatically position and test the height Positioning laser Determine the positioning spot, and ensure that the test point is aligned with the spot The mouse can control the platform, and the position clicked by the mouse is the measured point High resolution probe makes the analysis result better Good radiation shielding effect Test port highly sensitive sensor protection Technical indicators Any metal coating with element analysis range from sulfur (S) to uranium (U) Up to five coatings can be analyzed at one time Thin testable 0.005 μ m The analytical content is generally 2ppm to 99.9% The coating thickness is generally within 50 μ m (different for each material) Any number of selectable analysis and identification models Mutual matrix effect correction model Multivariable nonlinear recovery program High long-term stability The temperature range is 15 ℃ to 30 ℃ Power supply: AC 220V ± 5V, AC purified regulated power supply is recommended Instrument size: 576 (W) x 495 (D) x 545 (H) mm Weight: 90 kg The energy dispersive X-ray fluorescence spectrometer series is used in electroplating detection industry to meet the demand: (1) Analyze the coating thickness detection and electroplating solution analysis; (2) Rapid detection can be carried out for RoHS harmful element detection, heavy metal detection, tank liquid impurity detection and online water quality monitoring to detect whether the heavy metals in the environment are * * standard. It also has the following characteristics Fast: the thickness of sample coating can be measured in 1 minute, and the measurement accuracy requirements can be met. Convenience: some models of the X-ray fluorescence spectrometer use the electrically cooled semiconductor detector on the imported * *, with energy resolution higher than * * 135eV and high test accuracy.In addition, there is no need for liquid nitrogen refrigeration and regular supplement of liquid nitrogen. The operation is more convenient and the operating cost is lower than other similar products. Non destructive: the sample has no change in any form before and after the test. Intuitive: real-time spectrogram, which can visually display element content. Wide test range: X-ray fluorescence spectrometer is a physical analysis method, and its analysis is independent of the chemical binding state of the sample.Elements belonging to the same group in chemical properties can also be analyzed, and vacuuming can be used to test from Na to U. High reliability: because no one interferes with the test process, the instrument has high analytical accuracy, repeatability and stability.Therefore, its measurement reliability is high. Meet different needs: the test software is Windows operating system software, which is easy to operate and powerful. The software can set the instrument status, set the instrument parameters, and has a variety of analysis methods. The working curve production methods are flexible and diverse, which is convenient to meet the test needs of different customers and different samples. *Compared with chemical analysis instruments, X-ray fluorescence spectrometer has advantages in overall use cost, which can be accepted by more enterprises and manufacturers. Simple: low technical requirements for personnel, simple and convenient operation, and simple and convenient maintenance. The coating thickness gauge is a new type of instrument carefully designed for coating thickness measurement.It is mainly used for: thickness measurement of metal coating, determination of electroplating solution and coating content;Detection of gold, platinum, silver and other precious metals and various ornaments. Performance advantages Precise 3D platform Sample observation system of Image recognition based on Easy detection of deep groove samples Four kinds of micropore focusing collimators, automatic switching Dual protection measures for seamless collision avoidance Large area high-resolution detector is used to effectively reduce the detection limit and improve the test accuracy Full automatic intelligent control mode, one key operation! Automatically exit self check and reset after startup Cover opening automatically exits the sample table and raises the Z-axis test platform to facilitate lofting Close the cover and push the sample table, lower the Z-axis test platform and automatically focus Directly click the panoramic or local scene image to select the test point Click the software interface test button to automatically complete the test and display the test results 3. Technical indicators Analytical element range: from sulfur (S) to uranium (U) Simultaneous detection of elements: 24 more elements, up to five layers of plating Detection limit: up to 2ppm, 0.005 μ m when thin Analytical content: generally 2ppm to 99.9% Plating thickness: generally within 50 μ m (different for each material) Repeatability: up to 0.1% Stability: up to 0.1% SDD detector: resolution as low as 135eV The adopted micro hole alignment technology has a small aperture of 0.1mm and a small spot of 0.1mm Sample observation: equipped with panoramic and local industrial HD cameras Collimator: 0.3 × 0.05mm, Ф 0.1mm, Ф 0.2mm and Four kinds of Ф 0.3mm collimator combinations Instrument size: 690 (W) x 575 (D) x 660 (H) mm Sample chamber size: 520 (W) x 395 (D) x 150 (H) mm Sample table size: 393 (W) x 258 (D) mm X/Y/Z platform speed: rated speed 200mm/s, speed 333.3mm/s Repeated positioning accuracy of X/Y/Z platform: less than 0.1um Operating environment humidity: ≤ 90% Operating ambient temperature 15 ℃~30 ℃ http://skyray1013.b2b168.com