Uploaded on: April 28, 2020 18:59:58 come from: Water supply and drainage / Water supply and drainage construction design / construction plan
zero
3 points

Content Introduction: # 1 boiler of a power plant phase I 2 × 600MW unit project in Inner Mongolia is a HG-2072/17.5-HM8 subcritical pressure, primary intermediate reheat, single furnace, controlled circulation drum boiler designed and manufactured by XXX Boiler Co., Ltd. introduced from CE Combustion Technology Company of the United States; The maximum continuous evaporation capacity of the boiler is 2070T/H. In order to remove the oxide skin formed in the manufacturing process of boiler equipment, corrosion products, welding slag generated in the storage, transportation and installation process, and various attachments such as anti-corrosion agent coated on the equipment when leaving the factory; At the same time, remove the impurities that enter and remain in the equipment during manufacturing and installation, such as sand, soil, insulation materials, etc., to ensure the cleanness of the boiler water and steam system and the good quality of boiler water and steam during operation, and shorten the test run time. According to the standards required by the Guidelines for Chemical Cleaning of Boilers in Thermal Power Plants, the boiler shall be chemically cleaned before startup. The boiler is installed by Inner Mongolia XX Company. XX Co., Ltd. will carry out chemical cleaning in cooperation with XX Co., Ltd., and it is proposed to adopt the cleaning process of hydrochloric acid cleaning, citric acid rinsing, ammonia adjusted pH hydrazine passivation for chemical cleaning after negotiation.

 Boiler chemical cleaning construction scheme - Figure 1

Boiler chemical cleaning construction scheme - Figure 1

 Boiler chemical cleaning construction scheme - Figure 2

Boiler chemical cleaning construction scheme - Figure 2

 Boiler chemical cleaning construction scheme - Figure 3

Boiler chemical cleaning construction scheme - Figure 3

 Boiler chemical cleaning construction scheme - Figure 4

Boiler chemical cleaning construction scheme - Figure 4

 Boiler chemical cleaning construction scheme - Figure 5

Boiler chemical cleaning construction scheme - Figure 5

Click to download the source file now

Special statement: This material belongs to the sharing uploaded by users Downloaded content, only for learning, not for commercial use. If there is any copyright problem, please timely contact Station delete!

Collection
share

WeChat code scanning and sharing

Click to share

Click to see more
All comments I want to comment
No comment