Key points of high-rise structure overrun review (Word format)
1. Basic information (including: construction unit, project name, construction site, building area, application date, survey unit and qualification, design unit and qualification, contact person and method, etc.) 2. Seismic fortification standards (including fortification intensity or design ground motion parameters, seismic fortification classification, etc.) 3. Basic data of survey report (including: site category, equivalent shear wave velocity and overburden thickness, liquefaction discrimination, bearing stratum name and burial depth, foundation bearing capacity and foundation scheme, adverse section evaluation, etc.) 4. Overview of foundation design (including: foundation type of main building and podium, buried depth of foundation, thickness of basement floor and roof, pile type and single pile bearing capacity, main section of cushion cap, etc.) 5. Layout and selection of building structure (including: height and number of floors of main building, height and number of floors out of roof, height and number of floors of podium, size of super large roof; setting of seismic joints; The regularity of building plane and vertical; Whether the structure type belongs to complex type; The form of super large roof structure; Seismic grade of concrete structure, etc.)