VIP exclusive Full set of electrical construction drawings of a large well-known museum (well-known design institute)
nine
This drawing is a complete set of electrical construction drawings for large well-known museums (well-known design institutes), with a total of 97 sheets. The museum has five floors above the ground and three floors below the ground, with a building area of 29858.8 square meters. It is a Class I building with a fire rating of Class I. The first to fourth floors in the west of the building are arranged with logistics office rooms, research rooms, conference rooms, multimedia demonstration halls, etc. Exhibition rooms and reception halls are arranged in the middle and east of the building. Temporary exhibition halls are arranged on the first to third floors, fixed exhibition halls are arranged on the fourth floor, and entrance halls and reception rooms, bookstores, coffee areas are arranged on the first and second floors near the main entrance. The north side of the basement is equipped with electromechanical equipment room, with a floor height of 6m. The south side of the basement is a collection warehouse. The basement of the building is equipped with a Grade 5 Grade 2 civil air defense shelter and a Grade 5 civil air defense material warehouse. The construction area of this project is 29995 square meters. The basement is the equipment room and the collection warehouse, of which the collection warehouse area is for civil defense in wartime; There are four floors on the ground, some of which are for logistics office, and the rest are museum halls. The cornice height of the building is 25.3 meters, and the height of each floor: 9 meters for the underground collection warehouse, 6 meters for the equipment room, and 2.19 meters for the pipe interlayer locally; 5.4m from the first floor to the third floor and 7.4m from the fourth floor; The structural type is frame structure. Design scope: (1) 10/0.4KV power transformation and distribution system; (2) Power and lighting distribution system; (3) Lightning protection, grounding system and safety of buildings; (4) Monitoring system of power transformation and distribution facilities; Weak current design includes the following contents: communication system; Building automation system; CATV system; Security system; Public and emergency broadcasting system; Automatic fire alarm and fire linkage system; Leakage fire alarm system, multimedia environment and display system (audio system, conference system, multimedia display, navigation system) and building equipment integrated management system.