Design description: Yes Building function: residential Height category: high-rise building Number of floors above ground: 18 Drawing depth: construction drawing Number of drawings: 8 Design time: before 2006 Basement use: civil air defense, garage Domestic water supply design: domestic water supply system Fire protection design: indoor hydrant system Water supply mode: municipal water supply, variable frequency water supply, district water supply Water supply zone: Zone 3 Water consumption of fire hydrant outdoor (L/S): 15 Water consumption of fire hydrant indoor (L/S): 20
Brief introduction to building water supply, building drainage, air-conditioning condensate, indoor hydrant system The first to ninth floors above the ground are residential buildings. The building height is 26.55m, the number of residential households is 40, and the building volume is about 13740m3 Water supply system: water source: the municipal water supply pipe is used to supply domestic water and indoor and outdoor fire water for the community. The inlet pressure of the municipal water supply pipe is 0.30 MPa. Water consumption: the maximum daily water consumption of the building is 35 m3/d. The first to sixth floors of the building are directly supplied by the municipal water supply pipe. The water meters are centralized in the ground water meter wells on the first floor, and the rest are divided into two zones: the seventh to twelfth floors of Zone I, and the thirteenth to eighteenth floors of Zone II, The water is directly supplied by the non negative pressure frequency conversion automatic booster water supply equipment, that is, the water is supplied from down to up to the water supply point. The pressure of each water consumption point should not be greater than 0.35 mPa Drainage system: indoor sewage and waste are combined, and the sewage is discharged into the municipal sewage pipe after being treated in the septic tank. The daily sewage discharge of buildings is calculated as 90% of the maximum daily domestic water supply. The rainwater and sewage of the project are discharged separately. The roof rainwater is provided with a rainwater bucket, and the terrace is provided with a ground drain connected to the rainwater riser, which is discharged to the outdoor rainwater well. The air-conditioning condensate is set separately and indirectly discharged to the rainwater system of the community Fire hydrant system: water consumption of fire hydrant: 5L/S for indoor and 20L/S for outdoor of this building, with fire duration of 2h. Fire hydrants are set on each floor of this building according to the specifications, and the arrangement of fire hydrants ensures that two solid water columns arrive at any protected position indoors at the same time. A pump adapter is set outdoors to connect with the indoor fire hydrant pipe network. The fire pool pump room is set in the basement, and the total fire water consumption is 396m Water Supply and Drainage Construction Drawing of Building 32 in a Community Water Supply and Drainage Construction Drawing of Building 32 in a Community