1. The project is Hezhou Zhengling KTV Club, which has three floors in total, with a building area of about 5800 square meters and an air conditioning area of about 3350 square meters. The first floor is the reception hall, kitchen, etc. (the banquet hall is not in the scope of this design), the second floor is the banquet hall and luxury large rooms, and the third floor is the luxury large room and presidential room.
2. This preliminary design drawing includes the air conditioning and new exhaust design of the first to third floors.
3. The air conditioning system adopts four 130KW air-cooled module cold (hot) water units, which are placed on the roof.
4. The air conditioning mode of fan coil unit and air conditioning box plus independent new system is adopted. The air distribution of supply air is upward supply and upward return, and the return air of fan coil unit and air conditioning box is provided with return air box.
5. Including design description, system flow chart, equipment list, plan and detail drawing.

 Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 1

Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 1

 Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 2

Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 2

 Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 3

Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 3

 Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 4

Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 4

 Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 5

Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 5

 Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 6

Air conditioning and ventilation preliminary design drawing of KTV club on the third floor in Hezhou (12 sheets) - Figure 6

Click to download the source file now

Special statement: This material belongs to the sharing uploaded by users Downloaded content, only for learning, not for commercial use. If there is any copyright problem, please timely contact Station delete!

Collection
share

WeChat code scanning and sharing

Click to share

Click to see more
All comments (1) I want to comment
  • six

    abcxyh1990 LV2

    Generally,

    2015-11-14 15:45:00
Click to view more discussions