Constant temperature and humidity incubator It is a kind of commonly used laboratory equipment, mainly used for experiments and research in biology, medicine, agriculture and other fields. In order to ensure the normal operation of the equipment and extend its service life, it is necessary to carry out routine maintenance. Here are some specific suggestions:
1. Cleaning equipment: regular cleaning Constant temperature and humidity incubator To keep the equipment clean. You can use a soft cloth or sponge dipped with an appropriate amount of detergent to wipe, but you should avoid using highly corrosive detergent. At the same time, hard objects shall not be used to scratch the equipment surface to avoid scratching the equipment. 2. Check the water source: distilled water or deionized water is required, so the water quality in the water tank should be checked regularly to ensure that the water quality is clean. If impurities or discoloration are found in the water, the water source shall be replaced in time.
3. Check the humidity sensor: the humidity sensor is a key component for controlling humidity, and its working condition should be checked regularly. If the humidity sensor is found to be abnormal, it shall be cleaned or replaced in time.
4. Check the temperature sensor: the temperature sensor is a key component to control the temperature of the constant temperature and humidity incubator, and its working condition should be checked regularly. If the temperature sensor is found to be abnormal, it shall be cleaned or replaced in time.
5. Check the heating and cooling system: the heating and cooling system is the core part, and its working condition should be checked regularly. If any abnormality is found in the heating or cooling system, it shall be repaired or replaced in time.
6. Check the circuit system: the circuit system is the control center, and its working status should be checked regularly. If any abnormality is found in the circuit system, it shall be repaired or replaced in time.
7. Avoid overload: During use, avoid overload to avoid affecting the normal operation and service life of the equipment.
8. Avoid vibration: During use, avoid strong vibration to avoid affecting the normal operation of the equipment.
In general, for Constant temperature and humidity incubator Carry out daily maintenance, mainly including cleaning equipment, checking water source, checking humidity and temperature sensors, checking heating and cooling systems, checking circuit systems, avoiding overload and vibration, etc. These measures can effectively ensure the normal operation of the equipment and extend its service life.