Which is the best way to defrost? The electrostatic defrosting cabinet is a device that uses high voltage electrostatic field to defrost food. Its working principle is to set a high voltage electric field (generally 10KV-30KV) in a low temperature environment, so that the water molecules in food are subject to electrostatic force, thus improving the defrosting rate. 넶 one 2024-09-26 -
Negative ion generator: a magic assistant to improve indoor air quality With the rapid development of China's economy and the improvement of people's living standards, more and more people begin to pay attention to indoor air quality. According to statistics, modern people spend 90% of their time indoors, and indoor air pollution is often more serious than outdoor. In order to improve indoor air quality, negative ion generator came into being. This article will introduce the working principle, advantages and application scenarios of the anion generator in detail. 넶 one 2024-09-25 -
What are the common signs of the failure of the high-voltage package? 1. The output voltage is unstable: if the output voltage of the electronic pulse high-voltage package fluctuates greatly, it may be a sign of aging of internal components.
2. Energy output decline: the energy output of the high voltage package decreases, which may lead to the reduction of equipment efficiency, indicating that the performance of the high voltage generator may decline.
3. Overheating: overheating of the high-voltage module during operation may be a signal of internal circuit failure or poor heat dissipation.
4. Abnormal noise: abnormal noise occurs during the operation of the booster module, which may be a sign of loose or damaged internal components.
5. The insulation performance decreases: if the insulation performance of the high-voltage package decreases, leakage may occur, which is a sign of potential safety hazards.
6. Frequent triggering protection mechanism: If the electronic pulse high-voltage package frequently triggers overvoltage, overheating and other protection mechanisms, it may indicate that it has faults.
7. Physical damage: if there is obvious damage, corrosion or deformation on the appearance of the high-pressure generator, it may be the external manifestation of the fault.
8. Connection problem: loose or oxidized connection points of high-voltage modules may lead to poor contact and affect the normal operation of equipment.
9. Gradual decline in performance: with the passage of time, the performance of the booster module gradually declines, which may be a natural process of component aging. 넶 five 2024-09-25