Guangzhou Tianwei Trade Co., Ltd Main products: recorder, regulator, pressure sensor, pressure switch, pressure gauge, thermocouple, thermal resistance, flowmeter, radiation sensor, portable test type, moisture meter, balance, labeling machine, carbon tape, dust particle counter, strain gauge, emergency tester, portable trace oxygen analyzer, electrostatic test analyzer, gas analyzer, gas flowmeter Motor, acceleration sensor, displacement sensor, portable dissolved oxygen meter, conductivity Rate meter, temperature and humidity probe, temperature and humidity recorder, defoamer, centrifuge, coating machine, coating machine, pressure gas analyzer and other instruments; Chemical and chemical standard stock solution and analytical reagent; Standard signal generator, constant temperature oil bath, constant temperature water bath, constant temperature and humidity test chamber; Industrial filter, filter disc, connector
Service telephone
eighteen billion one hundred and forty-eight million six hundred and two thousand and eighty-four
Location:
product details

Paper recorder

  • If you are interested in this product, you can
  • Product name: Paper recorder
  • Product model: µR10000
  • Product exhibitors: YOKOGAWA
  • Product documentation: No related documents
Brief introduction

YOKOGAWA paper recorder µ R10000 µ R1000/µ R1800 UR10000 UR20000 436101 436102 436103 436106 437101 437102 437103 437104 437106 437112 437124 paper recorder

Product description

——UR10000/UR20000 continues the function of μ R1000/μ R1800

——High reliability of recorded data
——Large screen VFD clear display
——Display operation wizard to realize dialog operation setting
——Standard lighting device in the machine, new recording paper box
——Powerful computing function
——Network function
——Application software
——Free software upgrade
——Rich recording and printing functions
——New functions (input value correction, 24VDC/AC power supply, portable model)

——Electronic data storage (SD memory card) * New! Is expected to be released in mid February 2015!



Characteristics—— Continues the characteristics of advanced recorders

Important specifications of μ R1000 and μ R1800 are reserved

 

μR ten thousand

μR20000

Enter the number of points

Pen style: 1-4

Punctuation: 6 o'clock

Pen style: 1-4

Punctuation: 6 o'clock, 12 o'clock, 18 o'clock, 24 o'clock

Profile
Dimensions

Overall dimension

144 (W) x 144 (H) x 220 (D) mm (same as uR1000)

288 (W) x 288 (H) x 220 (D) mm (same as uR1800 )

Front cover

Dust and drip proof front cover (IP-54)

Connect Point location

Same as μ R1000

Same as μ R1800

Contact arrangement

4 mm screw terminal
Input terminal: same dot type, unified pen type and dot type
Optional terminal: the same
Power terminals: the same

Weight

2.1 kg (1), 2.2 kg (2), 2.3 kg (3),

2.4 kg (4 strokes), 2.5 kg (6 strokes)

7.5 kg (1), 7.5 kg (2), 7.6 kg (3)

7.6 kg (4 strokes), 8.4 kg (6 strokes), 8.6 kg (12 strokes),

8.8 kg (18 points), 9.0 kg (24 points)

Power supply

Rated power supply

100~240 VAC (automatic switching) (same as μ R1000/μ R1800)

Power consumption

Pen type about 40 VA
Dotted type about 40 VA
Pen type about 55 VA
Dotted type: about 55 VA

Fuse

Maintenance free fuse

Accessories

Pen, writing pen, box ribbon, recording paper, shunt resistor

Mounting bracket (same as μ R1000)

Pen, writing pen, box ribbon, recording paper, shunt resistor

Mounting bracket (same as μ R1800)

Removable felt pen, writing pen or box ribbon

Achieve high reliability record

Servo unit - the driving structure of micro stepping motor, gear and rack is adopted, which eliminates the transmission belt, thus greatly reducing the volume and power consumption of servo unit.

 Servo unit

The front cover of the recorder is dust-proof and drip proof (in accordance with DIN 40050-IP54 standard) - when installed on the instrument panel, the exposed parts such as the front cover of the recorder meet the dust-proof and drip proof standards. The environmental adaptability has been improved.

 Splash-proof Front Door µR10000

High voltage semiconductor relay - an electronic scanner that realizes the switching of input signals. High voltage semiconductor relay is used. It realizes 6-channel high-speed scanning, prolongs the service life of the scanner, and realizes no noise.

Application specific integrated circuit (ASIC) - Yokogawa Electric's proprietary ASIC * is used to achieve high integration, greatly reduce the power consumption and heat generation of the product, and extend the service life of the parts.

 Use of ASICs

**Standard/EMC standard - Yokogawa Electric's high reliability industrial recorder complies with * * standard and EMC (electromagnetic compatibility) standard. And meet the CE standards of European market.

Yokogawa CCS EMI Laboratory

Lightweight design - because of the adoption of * new die technology, the number of machine parts is reduced and the weight of the machine body is effectively reduced. At the same time, through the use of ASIC and new servo units, the efficiency of all pen and dot models is improved, and the heat generation is reduced.

µR10000

µR20000

VFD large screen dot matrix display

The display is easy to view and supports the user's on-site monitoring.
VFD 101 × 16 large screen dot matrix display is adopted.
Various settings are carried out in a dialog mode, and the operation guide is displayed, which makes the setting operation easier.

Multi screen display of on-site monitoring (multiple different screens are displayed)

·Use the recorder as a monitor
µ R10000 - 6-channel simultaneous display (dotted model)
µ R20000 - 12 channel simultaneous display (12, 18 and 24 channel dotted models)
2-channel simultaneous display
4-channel simultaneous display
·Monitor the recording position through analog display - pointer display
µR10000
µR20000
·Centralized monitoring of alarm status - channel alarm status display
µR10000

µR20000

Easy setting through operation wizard —— Various parameters are set in the way of dialogue and wizard, providing users with a user-friendly setting interface, which is easier to operate.

Provide wizard display for settings (Example: range setting)

Upper part (setting item):
Display the settings of channel, range, Span (left) and Span (right).
Lower part (set navigation):
Display the description and setting range of each item.
μ R10000: scrolling display with more than 18 characters.
μ R20000: scrolling display with more than 31 characters.





Interior lighting—— High brightness white LED lighting device is standard in the machine, High brightness white LED lighting device is standard in the machine, which greatly improves the readability of recorded data.

New record paper box—— A new type of recording paper box is adopted, which can easily pull out the recording paper for viewing even during the recording process.

μR10000 μR20000

Operation function—— The calculation results can be recorded in simulation

Pen style: The measurement results and calculation results of any felt pen can be recorded.

Punctuation: All channels (12 channels) can be analog recorded. In addition, the recording function of each channel can be turned on/off.

Example of dotted analog recording

Powerful computing function

transport Computing channel

Use measurement channel, communication digital input, remote input.

Number of operation channels

Pen style (8 passageway ) , dotted (μR10000:12 Channel μR20000:24 passageway )

Operation type

Four rules, square root, good value, common logarithm (y=log10x) , Index (eX) , power relation operation (< > =≠) Logical operation (AND OR NOT XOR)

constant

thirty individual

Communication digital input

Pen style :8 Individual, dotted :12 individual (μR10000) twenty-four individual (μR20000)

Remote input

five No more than remote inputs.
Remote status can be used in formulas (0/1)

formula

one hundred and twenty Within characters

Statistical operation

MAX MIN AVE SUM MAX-MIN

Network function


Rich recording and printing functions

Print example

μR10000

4-pen model

6-channel dotted model
μR20000

24 channel dotted model

Partial compression and expansion record
You can zoom in and record the part that needs to be recorded in detail.

Partition record
Record different channels in different areas on the recording paper.

Correction of input values (option/CC1)

When the performance of the sensor declines, the measured data needs to be corrected due to deviation from the true value, or it is within the accuracy range but has deviation from the display data of other instruments, fine adjustment can be made.

Calibrate with the specified measurement input signal as the reference, and take it as the measured value.

Set number of points
The number of points (including starting point and ending point) that can be corrected is set in 2-16.
Use deviation value setting


Use good value setting
 Use deviation value setting  
Correction value of the fourth correction point (B4)=a-b

Example of input values

Input value After correction Deviation value Excellent value
9.8° 10.0° 0.2° 10.0°
90.5° 90.0° -0.5° 90.0°

24VDC/AC power drive (option/P1)

24VDC or 24VAC power supply can be used.

  • Rated power voltage: 24VDC/AC
  • Power voltage range: 21.6~26.4 VDC/AC
  • Rated power frequency (AC): 50Hz/60Hz
  • Withstand voltage: 1000VAC between power terminal and grounding terminal
  • Power consumption (approx.):
supply voltage *Large value
24 VDC Approx. 50 VA
24 VAC (50/60 Hz) About 60 VA

Portable model (option/H5 [])

Including carrying handle and power cord.

Part name

 Part name µR10000 Part name µR20000

  1. Handle
  2. Protective grounding terminal (standby)
  3. Attached power connector protective grounding terminal (connect the specified power cord)
  4. Feet (4)

Specifications
 Specifications

Header printing (optional/BT1)

Manufacturing process information and notes such as batch processing/batch number can be printed synchronously with simulation records.

Print example (pen model)

 Print example (pen model) *The µ R series can contain calculated values.

explain:

  • Batch name=batch number (characters) - batch number (4 or 6 digits)
    Example
    Batch No. - 00000 1
    Batch number Batch number (When the record is stopped, the user can automatically increase it by 1.)
  • Start printing/end printing: print in a way similar to manual printing (stop during analog recording).
  • Information printing: During analog recording, information containing measured * values can be printed.
    (Measurement * value, information string and date/time can be set arbitrarily.)

basic operation

  • When you start recording, start printing.
  • When recording is stopped, printing ends.
  • During analog recording, information containing measured * values can be printed.

The following figure shows the basic operation mode.

Basic operating mode

 Basic operating mode *The µ R series can contain calculated values.

Electronic data storage (SD memory card)
Software—— RXA10 setting software (sold separately)
At present, the RXA10 configuration software supports Windows Vista *, which can now be downloaded online and upgraded to R3.03 for free.

*Support for Windows Vista version
·Windows Vista Home Premium (64 bit version not included)
·Windows Vista Business (excluding 64 bit version)
It is more convenient to manage various setting inputs and setting information of measurement and calculation channels. Moreover, the settings can be input through the communication interface.

-It is easy to set the measurement channel, operation channel and other settings. Provide setting software (standard configuration) and setting software (with interface unit).
-It can be set systematically.  
-It can be set through the communication interface.

be careful
1: It cannot be used together with RS-422/485 communication interface.
2: USB interface of PC needs serial interface converter.
3: Please provide your own connecting cable.

DAQLOGGER high reliability data acquisition software


Through DAQLOGGER, 32 recorders/data collectors/controllers can be connected, Help users establish a real-time data acquisition environment with more than 1600 channels.


Monitoring software
Real time display of measurement data and calculation data on PC.

Build * a good monitoring environment.


Browser software
Re display, analysis, data conversion

Waveform printing and other operations are more convenient.


E-mail transmission
Send E-mail when the event occurs. Data, report

The instantaneous value or monitoring screen is added to E-mail.


FTP client function
When data files and report files are created,

It is automatically sent to the file server via FTP.

Model selection data


Product message
title
contacts
contact number
content
Verification Code
Click to change
Note: 1. You can use the shortcut keys Alt+S or Ctrl+Enter to send information!
2. If necessary, please leave your detailed contact information!
Copyright@ 2003-2024  Guangzhou Tianwei Trade Co., Ltd Copyright
Tel: 18148602084 (WeChat) Email: info@gzstwmy.cn   Address: Room 203, No. 483, Qingnian Road, Huangpu District, Guangzhou   QQ:1557719813

Yue ICP Bei No. 09026132