product details
  • Product name: ring main unit grounding wire - special grounding wire

  • Product model: JDX-WH3
  • Product manufacturer: Kerui
  • Product documentation:
You added 1 item View Cart
Brief introduction:
Shijiazhuang Kerui Electric specializes in producing various special grounding wires, including: cable branch box special grounding wire, ring network cabinet grounding wire - special grounding wire, central cabinet grounding wire, substation grounding wire, distribution grounding wire, transmission grounding wire, ring network cabinet grounding wire - special grounding wire, etc.
Details:

JLDQ-2-10KV cable branch box grounding wire Special grounding wire for cable branch box Ring network cabinet grounding wire

1、 Product Introduction

JLDQ-2 10KV cable branch box ground wire 10kv ring network cabinet special grounding wire multi-purpose series The product is advanced in design, reasonable in structure, perfect and reliable in performance, and easy to use. It is an ideal product for upgrading the power industry at home and abroad, and a necessary safety tool for power plants, substations, industrial and mining electrical departments

2、 Product classification

product It can be divided into Metric 12 # nut, 14 # nut, 16 # nut and three standard contact pins of the ring main unit can meet the requirements of the grounding link of the cable branch box as well as the selection and use of various equipment Other voltage levels can be customized. Abundant supply, fast shipment!

This ground wire Passed the type test in the electric power safety instrument testing center of electric power industry, and the main technical indicators meet ISO9001:2000 electric power industry standard and international IEC technical standard. The product has passed the provincial appraisal and the examination of the power industry, and is approved to be popularized and used in China.

Usage and precautions: According to the power industry DL/T879-2004 Technical Regulations

3、 Use and maintenance of grounding wire of sub branch box:

Before using the personal security line, the power supply should be checked to confirm that the power has been cut off, and the power supply should be carried out after confirming that there is no voltage on the equipment. First connect the grounding clamp to the grounding grid or flat iron piece, and then use the grounding rod to fasten the conductor end wires on the equipment conductors. When removing the short circuit grounding wire, the sequence is exactly opposite to the above. The distance between the installed short circuit grounding wire and the live equipment shall not be less than the new value specified in the Electric Power Safety Work Regulations in consideration of the impact of the grounding wire swing. It is strictly prohibited to use winding method for grounding short circuit without wire clamp. Portable short circuit grounding wire shall be kept properly. Before each use, carefully check whether it is in good condition, the soft copper wire is not exposed, and the nut is not loose, otherwise it cannot be used. The inspection cycle of portable short circuit grounding wire is once every five years, and the inspection items are the same as factory inspection. The portable short circuit grounding wire passing the test shall be judged according to the size of short circuit current and appearance inspection after being subjected to short circuit, and generally shall be scrapped.

4、 Technical indicators    

Environmental conditions for use

(1)  Ambient temperature: -25°C -70°C

(2)  Relative humidity: ≦100%

(3)  Applicable occasions: indoor and outdoor rain free weather

V Principles for selecting nuts for appliances    

In the actual use process, the appropriate nut model should be selected according to the model of the internal contact position of the branch box under the power environment, and the nut should be grounded before being connected to the contact point for use.

VI Comparison Table of DL-II High Voltage Grounding Wire Selection

Voltage level   Square number of grounding wire       Resistance per meter   

(KV)       (mm2)            ( )   

10          25              <0.79   

35          25              <0.79    

110         35              < zero point five six      

220         50              <0.40   

seven Electrical performance of grounding wire operating rod

Specifications     Leakage test     Leakage current    Withstand voltage

(KV)    (KV)         (μα)   (KV)

10       12           ≦10      40

35       42           ≦10      150

110      88           ≦10      250

220     176           ≦10      450

Note: withstand voltage time is After 1min power frequency withstand voltage, there shall be no local heating, flicker, breakdown deformation, etc.


Our company mainly produces Electroscope ground wire Security fence Insulation pad Personal protective equipment Signboard Insulated step stool Safety tool cabinet And other products

contact number: thirteen billion six hundred and three million two hundred and eleven thousand three hundred and sixty-nine

title:
Content:
contacts:
contact number:
Email:
corporate name:
Contact address:
 
 
Note: 1. You can use the shortcut keys Alt+S or Ctrl+Enter to send information!
2. If necessary, please leave your detailed contact information!

Alistore scanning code to add WeChat

Shijiazhuang Kerui Electric Co., Ltd
Factory headquarters: Duanjiazhuang, Jinzhou, Hebei
24-hour service phone: 13603211369 0311-85021355
Fax No.: 0311-85021277
Email: sjzkerui@163.com
Website: www.sjzkerui.com

Ji Gong Wang An Bei No. 13018302001138