QDY liquid ammonia emergency cut-off valve, QDY liquid ammonia emergency cut-off valve
Alternative name: Emergency shut-off valve Station emergency shut-off valve Hydraulic emergency shut-off valve Oil pressure emergency shut-off valve Emergency shut-off valve for ammonia Liquid ammonia emergency shut-off valve
Model: QDY421F-25C QDY421F-40C、QDY421F-25P、QDY421F-40P
Overview of emergency shut-off valve:
QDY421F-40C hydraulic liquid ammonia emergency shut-off valve is normally closed, which adopts a high inlet and low outlet structure and is used together with the hand oil pump. The emergency shut-off valve is opened by reciprocating the hand oil pump handle to increase the pressure, so that the medium can pass through. In case of other emergencies, the relief valve of the hand oil pump is opened, and the pressure of the oil pressure system is released quickly, so that the emergency shut-off valve is closed immediately. The internal structure is arranged to melt when the external temperature rises to ≥ 80 ℃, block the gas pipe, and the valve is depressurized and closed for safety protection.
![QDY421F-40CDN25 Hydraulic Liquid Ammonia Emergency Stop Valve QDY421F-40CDN25 Hydraulic Liquid Ammonia Emergency Stop Valve](/uploads/2105/1-21052G5061A50.jpg)
QDY421F-40CDN25 Hydraulic Liquid Ammonia Emergency Stop Valve
Pressure rating: 4.0MPa
The working pressure of oil cylinder shall not exceed: ≤ 6.0.Mpa
Service temperature: - 40~+80 ℃
Oil cylinder medium: mixed spindle oil, transformer oil
Service medium: natural gas, liquefied gas, liquid ammonia, gas
Closing time: 75 ± 5 ℃
Closing time: ≤ 3-5 seconds
Opening pressure of oil cylinder: ≥ 3.0MPa
Valve body: cast steel, stainless steel. 304,316,316L
Spring: 50CrVA (spring steel)
Oil cylinder, piston: chrome stainless steel
![QDY421F-40CDN50 Liquid Ammonia Hydraulic Emergency Stop Valve QDY421F-40CDN50 Liquid Ammonia Hydraulic Emergency Stop Valve](/uploads/2105/1-21052G50F12B.jpg)
QDY421F-40CDN50 Liquid Ammonia Hydraulic Emergency Stop Valve
"Shanghai Yonglong Valve Factory/" QDY421F-40CDN50 liquid ammonia hydraulic emergency cut-off valve is applicable to the pipelines of gas, ammonia and gas storage tank stations. The main structure uses V-shaped tetrafluoroethylene as the dynamic seal, packing pressing as the initial seal, and packing sealing performance increases with the rise of medium pressure. It has both self sealing function and no need for manual maintenance, and is suitable for high and intermediate pressure transmission pipelines. The internal design of the shut-off valve is inverted seal. When the valve is opened, the valve must be fully opened to make the inverted seal work to increase the service life of the packing. The shut-off valve adopts the way of high inlet and low outlet. The valve is light to open and its operating force is far less than that of ordinary cast steel valve.