Product classification
 Quick coupling anti falling device
Quick coupling anti falling device
 Thin ball valve
Thin ball valve
 Automatic exhaust valve
Automatic exhaust valve
 Low temperature stop valve
Low temperature stop valve
 Pneumatic emergency shut-off valve for ammonia
Pneumatic emergency shut-off valve for ammonia
 CS19H-25C steam trap
CS19H-25C steam trap
 Japan SMC air filter pressure reducing valve
Japan SMC air filter pressure reducing valve
 Gas emergency shut-off valve
Gas emergency shut-off valve
 Pneumatic cryogenic ball valve
Pneumatic cryogenic ball valve
 Ammonia stainless steel stop valve
Ammonia stainless steel stop valve
 Ammonia stop valve
Ammonia stop valve
 Air pressure reducing valve
Air pressure reducing valve
 Floating ball type automatic drainer
Floating ball type automatic drainer
 YG02-25 flow limiting valve
YG02-25 flow limiting valve
 Methane low-temperature electric regulating ball valve
Methane low-temperature electric regulating ball valve
 Ball valve
Ball valve
 Electric liquid ammonia shut-off valve
Electric liquid ammonia shut-off valve
 LPG stop valve
LPG stop valve

Contact Yonglong

Consulting hotline 021-57566219
  • Mobile: 15900658318
  • Fax: 021-57568296
  • Email: 1257073858@qq.com
  • Address: Nanting Highway, Fengxian District, Shanghai
  • 2788
 Snap valve

Snap valve

  • Valve model: HGLDF-16P HGLDF-25P、HGLDF-40P
  • Diameter specification: DN25, DN50, DN80, DN100
  • Structure: vertical
  • Valve body material: CF8/304 stainless steel
  • Nominal pressure: PN1.6MPa, PN2.5MPa, PN4.0MPa
  • Applicable temperature: - 30/+80 ℃
  • Scope of application: liquid ammonia, liquefied gas, gas, oil
  • Product features: anti slip, anti drag
Click Inquiry 021-57566219
product details
Pull off valve - safety pull off valve - lower loading arm pull off valve - fixed loading system pull off valve
English: Nottrennkupplungen split coupling
Model: HGLDF-16P HGLDF-25P HGLDF-40P
Overview of safety pull off valve:
The safety pull off valve (emergency release device) can prevent leakage accidents caused by accidental tensile fracture of the crane pipe and hose. Its application fields include ship to shore unloading, tank loading and unloading of roads and railways, and other fixed and mobile fluid storage devices, such as the connection between the crane pipe, fluid conveying arm and transport carrier.
 Safety pull off valve
Working principle of pull off valve of quantitative loading system:
The pull off valve of the quantitative loading system ensures the safety of fluid transportation to a large extent in the marine and land crane pipes. Through a simple and unique design, when the tension of the crane tube exceeds the bearing capacity of the bolt of the emergency pull off valve, the split coupling is disconnected at both ends of the crane tube, and the built-in check valve automatically closes to prevent leakage.
 Liquid ammonia pull off valve
Basic features of fuel dispenser pull off valve:
1. Enable the equipment to automatically and quickly disengage;   
2. The two parts can be effectively sealed after separation;   
3. The breaking force is stable, easy to repair, requires manual reset and can be used repeatedly.
 Lower loading arm pull off valve
Function of lower loading arm pull off valve:
The advantages of the lower loading arm pull off valve are that it can be triggered, the valve can be closed instantaneously, there is little leakage and relatively small pressure loss in case of danger. The breaking mechanism shall ensure that the equipment can be automatically and quickly disengaged in case of "emergency disengagement"; It is also necessary to ensure that there is a "buffer period" before separation, so as to avoid "separation" during routine operation, which will affect normal loading and unloading operations.
 Installation diagram of emergency pull off valve
Installation diagram of emergency pull off valve:
The emergency pull off valve is installed on the loading and unloading hose or equipment of chemical raw materials (such as liquid propane, ammonia, ethylene oxide, liquefied petroleum gas LPG, butadiene, industrial methanol, natural gas LNG, etc.). Due to misoperation or sliding, the emergency pull off valve will leave the work area without being separated from the hose (or equipment), Breaking the connecting pipe caused a large amount of leakage of raw materials, leading to a major safety accident; Or the tanker is being loaded and unloaded. If the tanker needs to escape from the site quickly due to sudden fire and other reasons, the tanker cannot be separated from the loading arm by normal methods, which will also lead to major personal and property safety accidents, resulting in economic losses and environmental pollution. In order to prevent accidents and reduce accident losses, the loading and unloading equipment is equipped with emergency release pull off valve, which is a major measure to ensure safety and environmental protection during the storage and transportation of raw materials. Under normal working conditions, when under a certain tension, the emergency release pull off valve will automatically and safely disconnect, and both ends will automatically close, without fluid leakage, to protect the safety of pipelines and equipment.

 Online Service