Product classification
 Automatic gas shut-off valve
Automatic gas shut-off valve
 Emergency liquid ammonia shut-off valve
Emergency liquid ammonia shut-off valve
 Ball valve
Ball valve
 SCZ50-A fire retardant vent cap
SCZ50-A fire retardant vent cap
 Emergency pull off valve of loading arm
Emergency pull off valve of loading arm
 Power failure reset and close the electric ball valve
Power failure reset and close the electric ball valve
 Soft seal wafer butterfly valve
Soft seal wafer butterfly valve
 Gas solenoid shut-off valve
Gas solenoid shut-off valve
 Emergency shut-off valve
Emergency shut-off valve
 Air drain valve of air compressor
Air drain valve of air compressor
 Pneumatic diaphragm single seat regulating valve
Pneumatic diaphragm single seat regulating valve
 Crane tube pull off valve
Crane tube pull off valve
 Electromagnetic gas emergency shut-off valve
Electromagnetic gas emergency shut-off valve
 Electric emergency shut-off valve
Electric emergency shut-off valve
 Methanol emergency shut-off valve
Methanol emergency shut-off valve
 Pneumatic emergency shut-off valve
Pneumatic emergency shut-off valve
 Anti static thread flame arrester
Anti static thread flame arrester
 check valve
check valve

Contact Yonglong

Consulting hotline 021-57566219
  • Mobile: 15900658318
  • Fax: 021-57568296
  • Email: 1257073858@qq.com
  • Address: Nanting Highway, Fengxian District, Shanghai
  • 2788
 Long stem low-temperature flange stop valve

Long stem low-temperature flange stop valve

  • Valve model: DJ41F-40P
  • Diameter specification: DN15~DN100
  • Structure: straight through
  • Valve body material: CF8/304 stainless steel
  • Nominal pressure: PN4.0MPa
  • Applicable temperature: - 196 ℃/+80 ℃
  • Application range: liquid nitrogen, liquid oxygen, liquid argon, refrigerant, liquefied petroleum gas
  • Product features: low temperature resistance, lengthened valve rod design to protect stuffing box
Click Inquiry 021-57566219
product details
Introduction to long stem low temperature flange stop valve:
DJ41F-40PDN50 flange cryogenic stop valve uses CF8/304 stainless steel as the shell, PTFE as the valve disc seal and packing seal, and the long rod design has the function of protecting the stuffing box of cryogenic valve, because the tightness of the stuffing box is one of the keys of cryogenic valve. If the stuffing box leaks, the cold insulation effect will be reduced, leading to the gasification of liquefied gas. In the low temperature state, with the decrease of temperature, the elasticity of the packing gradually disappears, and the leak proof performance decreases. Because of the medium leakage, the packing and the valve stem are frozen, which affects the normal operation of the valve stem. At the same time, the slurry packing will be scratched due to the upward and downward movement of the valve stem, causing the valve stem to leak in the switch action.
 Cryogenic valves - welded cryogenic long stem stop valve
Cryogenic valves - welded cryogenic long stem stop valve
Use of long rod low temperature flange stop valve:
DJ41F-40PDN50 low temperature stop valve is mainly used for on-off manual low temperature stop valve of storage tank and pipeline at - 40 ℃~- 196 ℃, mainly used for ethylene, liquefied natural gas device, natural gas LPG LNG storage tank, receiving base and satellite station, air separation equipment, petrochemical tail gas separation equipment, low temperature storage tank and tank car for liquid oxygen, liquid nitrogen, liquid argon, carbon dioxide, PSA oxygen generation and other devices. The exported liquid cryogenic media, such as ethylene, liquid oxygen, liquid hydrogen, liquefied natural gas, liquefied petroleum products and other mechanical equipment supporting facilities.
 Cryogenic valves - flanged long stem cryogenic stop valve
Cryogenic valves - flanged long stem cryogenic stop valve
Structural design of long rod low temperature flange stop valve:
The feature of DJ41F-40PDN50 long rod cryogenic stop valve is that its valve cover is generally of long neck structure, which is shown in the Technical Conditions for Cryogenic Valves (GB/T 24925) It is also clearly stipulated that "the valve covers of cryogenic gate valves, cryogenic globe valves, cryogenic ball valves and cryogenic emergency shut-off valves shall be designed into long neck valve covers that are convenient for cold insulation according to different operating temperature requirements, so as to ensure that the temperature at the bottom of the stuffing box is kept above 0 ℃". The design of lengthening the valve cover structure is mainly to keep the valve operating handle and stuffing box structure away from the low temperature zone, which can not only avoid frostbite caused by too low temperature, but also ensure that the stuffing box and gland can be used at normal temperature, prevent the sealing performance of the packing from decreasing, and extend the service life of the packing.
Related products: Low temperature emergency shut-off valve     Low temperature ball valve     Low temperature filter