ChargerLAB(www.chargerlab.com)It is an English website focusing on the charging field. Its brand "POWER-Z" launched a meter KT001 that can measure USB PD.This is another portable USB test instrument after POWER-Z KM001 and POWER-Z FL001.This meter can be used to test the charging voltage and current of all mobile phones, power banks, chargers, laptops and tablets using USB PD Type-C.Support QC3.0, QC2.0, AFC, FCP, PD triggering and have automatic protocol detection function.
The latest version (manual version V1.03, PDF format):Click Download
2、 Computer end software download
Download address of the latest version (V1.79.6):Please click(Extraction code: j1k4)
3、 FAQ
Q: No response when the tester is connected to the computer/no virtual serial port is prompted/waiting for connection
A: Please read the instructions carefully first, and then check in the following order: 1. The port connected to the tester is incorrect, and it is not connected to the computer interface;2. If the computer system is Windows7 or MAC, it will lead to incompatibility. You must change to a system above Windows8. Windows10 is recommended;3. The driver is not installed, please install the driver;4. The power supply on the front panel of the chassis is insufficient to transmit data. Change to the USB interface on the back of the chassis, or try to change to a desktop computer;5. Replace the data cable. The current data cable may have no data function and can only supply power.
Q: The tester is connected to the C-C line separately, and the point is not bright/PD cannot be measured/cable cannot be measured
A: Turn on the PD switch at the lower right corner to supply power to the independent power supply port.
Plug head A of KT001 into the charger, and when the USB-C OUT port is connected to the C-C cable output, it only supports the charging of the monitoring mobile phone or notebook, but does not support the charging of the C-port mobile power supply (does not support forced charging). If you want to monitor the charging of the C-port mobile power supply, you need to use the USB-C IN port as an input.
To change the display language to another language, long press the middle key, turn to the bottom to select a language, enter, select the desired language and press the middle key to confirm.
To upgrade the firmware, connect the tester to the computer, open the computer software, and select Advanced - Firmware Upgrade
4、 KT001 Brick Rescue Tutorial
When the KT upgrade fails and the boot card is on the above interface, first move the scroll wheel to the right and press it, then connect KT to the computer, open the computer software, and ignore the prompt of waiting for the device connection
As long as the tester's drive letter appears on my computer, the bricks can be saved. If the tester's drive letter does not appear, install the driver in the software first (copying non firmware files to the tester's storage space is strictly prohibited!!!)
Click Advanced - Firmware Update, then you will be prompted whether to update, and select Yes
When some testers save bricks, the version of Unknown will be displayed in the red box in the figure, which is ignored.
After clicking Yes, the machine will start to be forced to be refreshed. After the refresh is successful, the tester will automatically restart, indicating that the upgrade is successful.