FTC320 Ex hydrogen purity analyzer

You added 1 item View Cart
Brief introduction
The FTC320 EX hydrogen purity analyzer of Messkonzept Company in Germany can work at an ambient temperature of - 20 ° C to+50 ° C, with a withstand voltage of up to 20 bar. For the measurement of hydrogen in nitrogen, the small measurement range of zui is 0 to 0.3 vol.% (3000 ppm). It can be set to allow switching between different measurement tasks. FTC320 has an efficient cross sensitivity compensation program, which can flexibly adapt to their respective measurement tasks. It requires an external voltage signal as an input variable to reflect the concentration of gas components causing cross sensitivity. The drift is 1% of the full scale, the noise can be increased from 50ppm (FTC300) to 5ppm (FTC320), and the temperature dependence of 5 ppm/° C is also significantly lower than that of 50 ppm/° C of FTC300.

FTC320 Ex hydrogen purity analyzer

Detailed description of

Messkonzept FTC320 EX Hydrogen purity analyzer

-For Ex Zone2 Ex II3G nR IIC T4 Gc hazardous areas



Technical data download of Messkonzept GmbH hydrogen purity analyzer

FTC320 is Germany MESSKONZEPT GMBH The company's new generation thermal conductivity hydrogen purity analyzer. And classic FTC300 In contrast, the measurement accuracy is improved by using new electronic components. The FTC320 hydrogen purity analyzer has reduced the measurement noise. This is particularly important for measurements in the trace range. FTC320 can realize new measurement tasks. In particular, the possibility of cross sensitivity compensation using external signals has expanded. Larger program memory and greater computing power make this possible. A good example of a practical application is the use of an additional oxygen module for oxygen measurement. The increased computing power of FTC320 allows real-time cross sensitivity compensation.
For more intuitive use, the operation menu has been slightly modified. Like the classic FTC300 Hydrogen analyzer Similarly, data can be accessed through the RS232 interface. The installation dimension and analog interface (4-20mA, 0-10V and relay) are the same as FTC300. Users familiar with FTC300 will soon start using FTC320 Hydrogen purity analyzer
FTC320 Ex explosion-proof hydrogen purity analyzer approved Ex-Zone2 Ex II3G nR IIC T4 Gc, FTC320 Ex are FTC320 approved for Zone 2 according to ATEX Directive 2014/34/EU. FTC320 series analyzers with corresponding certification bear the following marks: II3G Ex nR IIC T4
The explosion-proof FTC320-EX hydrogen purity analyzer has the same functions, operation and measurement characteristics as FTC320. The declaration of conformity declared by the manufacturer of the measurement concept was issued by TUV SUD on August 10, 2020. The basic test proves the applicability of FTC320 product series for explosion-proof "nR" (steam proof equipment) enclosure.

FTC320 explosion-proof type Hydrogen purity analyzer And argon analyzer are Messkonzept from Germany GmbH's new generation thermal conductivity gas analyzer can further improve its measurement accuracy. FTC320's new electronic equipment and software allow up to 99 pairs of test components to be completed with the same instrument, and expand oxygen (O2) measurement through additional modules. The explosion-proof EX version has passed the zone EX II 3G EX nR IIC T4 Gc certification.
The FTC320 has a comfortable operation menu, which can facilitate zero point and full range adjustment, parameterization and configuration. In addition, data can be operated and accessed through RS232 interface, and various analog signal inputs and outputs are also available.

Performance description of FTC320-EX explosion-proof hydrogen purity analyzer of Messkonzept Company in Germany:

  The FTC320 adopts a robust design with IP65 protection level. It can work at ambient temperature from - 20 ° C to+50 ° C, and withstand voltage up to 20 bar。 For the measurement of hydrogen in nitrogen, the small measurement range of zui is 0 to 0.3 vol.%(3000ppm)。 FTC320 thermal conductivity hydrogen purity analyzer can be set to allow switching between different measurement tasks. FTC320 has an efficient cross sensitivity compensation program, which can flexibly adapt to their respective measurement tasks. It requires an external voltage signal as an input variable to reflect the concentration of gas components causing cross sensitivity. FTC320 drift is 1% of full scale, and the noise can be increased from 50ppm (FTC300) to 5ppm (FTC320) The temperature dependence of ppm/° C is also significantly lower than 50 ppm/° C of FTC300.


Germany Messkonzept FTC320-EX explosion-proof Hydrogen purity analyzer performance Add on module: oxygen content measurement function

The additional oxygen measurement module expands the application range of FTC320 for oxygen containing non binary gases. Oxygen measurement is based on an electrochemical cell, which is lead-free, meets RoHS requirements, has a long life and is completely resistant to carbon dioxide interference. The electrochemical cell is sensitive to oxygen partial pressure. The output signal of the oxygen sensor is a digital signal, which is processed in FTC320. In order to provide a pressure independent output signal in volume%, the signal is compensated by the internal pressure sensor.