The single P leakage protection only controls the live line. How to protect if the zero line leaks electricity?

Date of issue: 2022-08-23 00:00:00      Author: Delixi Flagship Store
Summary: Generally speaking, the current of Delixi circuit breaker flows from the live line to the neutral line, which is a circuit. As long as the zero sequence potential is not detected, it will be considered as leakage and will trip.

Generally speaking Delixi Circuit breaker The current flows from the live line to the zero line, which is a loop. As long as the zero sequence potential is not detected, it will be considered as leakage and will trip.


Advantages of single P leakage protection: small size, if Power Distribution Box There are many packet switches. The single P has one less position than the double P, and several more branches can be connected in the same space.


Most of the double P with leakage protection are not marked with N, but they are generally connected to the left connecting wire and the right neutral wire. The wiring of the socket is just the opposite, and the left is neutral and the right is grounded in the fire. If the connection is reversed, it is OK. Dual P controls the on-off of the two lines.


However, some double P's do not have the N mark, and the position with the N mark must be connected to the neutral line to form a good wiring habit.


Advantages of double P with leakage protection: it is safer, and there is also an advantage that is easy to be ignored. Double P has stronger ability to identify overcurrent and overvoltage. It can play a more protective role of the air switch. Well, that's all for today's sharing. Thank you for watching. See you next time!

Related goods

  • Delixi lithium electric drill rechargeable electric hand drill household multi-function lithium battery electric hand drill impact pistol drill electric screwdriver
  • Delixi CDZJ DC contactor solenoid type structure is used for electric vehicle coil with high power consumption, which is generally used for intermittent working system [customized product]
  • Delixi ST shuttle valve shuttle valve pneumatic aluminum alloy shuttle valve ST/KS shuttle valve gas flow control valve logic valve
  • Delixi CDM3T transparent molded case circuit breaker transparent molded case air switch transparent air switch 3-pole rated 16A~630A partial specification order
  • Delixi CDPV2-32 Solar PV Fuse Base PV Fuse Base Solar PV System Protection Fuse Base [Customized Product]
  • Delixi auxiliary contact F4-22 F4-40 F4-04 F4-31 F4-13 CJX2/CJX2S special auxiliary contact for AC contactor