home page  >  Product supply  >  Electrician Electrical  >  High voltage apparatus  >  High voltage switch cabinet >High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell
  •  High voltage switchgear KYN28A-12 middle cabinet shell

High voltage switchgear KYN28A-12 middle cabinet shell

Price

MOQ

3300.00 yuan/set

1 set

  • Minimum order quantity: 1 set
  • Location: Wenzhou, Zhejiang
  • Price: electricity
  • Total supply: 8800 sets
  • Delivery period: 7 days
  • Published on: 09:01:02, May 21, 2019

Mr. Ruan: 086 -- 15988732362 (Please tell me when you contact me“ Building materials network See the information, there will be a discount! Thank you!)

Warm reminder: Consumers are requested to take epidemic prevention measures for international packages. The goods need three licenses and one report for imported goods (supplier's license, entry quarantine certificate, preventive disinfection certificate and NCV nucleic acid test report)

Detailed description

  • Processing customization:

    yes

  • Brand:

    other

  • model:

    KYN28A-12

  • Structure:

    Cabinet type

  • Rated voltage:

    12 kV

  • Rated frequency:

    50 Hz

  • Rated current of bus:

    6300 A

  • Product certification:

    cqc

High voltage switch cabinet Detailed description of KYN28A-12 central cabinet shell:

1、 Product introduction:

KYN28-12 (Z) (GZS1) armored removable AC metal enclosed switchgear is a complete indoor power distribution device with rated voltage of 3.6~12kV three-phase AC 50Hz. It is used for power transmission in power plants, power industry systems and power receiving and distribution in substations of industrial and mining enterprises, and can also be used to frequently start high voltage Motor Etc.
The switch cabinet can meet the requirements of GB3906, DL404, IEC-298 and other standards, and can prevent misoperation of the circuit breaker and load pushing handle "Five prevention" functions, such as preventing electrification from closing the grounding switch, preventing power transmission when the grounding switch is in the grounding position, and preventing entering the electrification interval by mistake.

2、 Environmental conditions for use:
Altitude: no more than 1000m;
Ambient temperature: upper limit 40 ℃, lower limit - 10 ℃;
Relative humidity: the daily average value is not more than 95%, and the monthly average value is not more than 90%;
Saturated steam pressure: the daily average value is not more than 2.2 × 10-3MPa, and the monthly average value is not more than 1.8 × 10-3MPa;
Seismic intensity: no more than 8 degrees;
Places without fire, explosion danger, serious pollution, chemical corrosion and severe vibration.

3、 Main features:
1) The cabinet structure is covered with aluminum Zinc plate It is assembled by multiple bending;
2) All operations are in the cabinet door Closed;
3) High level of protection, which can prevent sundries and pests from entering;
4) Simple and effective "five prevention" locking to prevent misoperation;
5) VS1 (ZN63A) or VD4 vacuum circuit breaker can be used according to user requirements;
6) It is easy to replace the circuit breaker, and the handcart has good interchangeability;
7) Reliable wall installation of the cabinet, maintenance in front of the cabinet, and reduction of floor area;
8) The cable room has sufficient space to connect multiple cables;
9) The quick earthing switch is used for earthing and circuit short circuit;
10) The circuit breaker room, relay room and cable room can be installed with heaters according to user requirements to prevent condensation and corrosion;
11) The circuit breaker room and cable room can be equipped with lighting devices according to user requirements to facilitate maintenance and overhaul.

I want to comment

Negative comments such as slander, malicious attack, unsubstantiated and non positive energy will be deleted by the administrator. Your comments may be of high reference value to others.

Related comments

Well received
0%
Neutral comment
0%
negative comment
0%
/ Number of records: 98   home page previous page next page Last

Disclaimer: The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legality of the content are the responsibility of the publishing enterprise. www.chinabuildingmaterials. com does not assume any guarantee responsibility for this. In order to protect your interests, we suggest you choose the building materials link member of China Building Materials Network. Friendly reminder: New and old users are requested to strengthen the screening of the authenticity of information and the identity and qualification of its publisher to avoid unnecessary disputes and losses!

I want to join

Online inquiry
  • Zhejiang Mingcabinet Electric Co., Ltd

  • High voltage switchgear KYN28A-12 middle cabinet shell