home page  >  Product supply  >  Instruments and Apparatuses  >  Indoor environmental protection testing instrument  >  Other indoor environmental protection testing instruments >Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator
  •  Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator

Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator

Price

MOQ

1.00 yuan/set

1 set

  • Minimum order quantity: 1 set
  • Location: Wuxi, Jiangsu
  • Price: electricity
  • Total supply: 1000 sets
  • Delivery period: 3 days
  • Release time: 2015-12-07 13:25:06

Gong Sheng: 13812522260 (Please tell me when you contact me“ Building materials network See the information, there will be a discount! Thank you!)

Warm reminder: Consumers are requested to take epidemic prevention measures for international packages. The goods need three licenses and one report for imported goods (supplier's license, entry quarantine certificate, preventive disinfection certificate and NCV nucleic acid test report)

Detailed description

  • Processing customization:

    yes

  • Brand:

    KSA

  • model:

    WMKY-2000T

  • Measurement range:

    0-20PPM

  • Measurement object:

    chlorine

  • Measurement accuracy:

    5%

  • Size:

    155 mm

  • Weight:

    1 kg

  • Scope of application:

    petrochemical industry

Wuxi Keshian Electronics is now offering preferential promotion pin Activity, combustible gas detector The low price is coming. Just call the sales contact information * * *, and the price will drop to the bottom. The gas detectors produced by our company are all imported sensors, with quality assurance, and free maintenance and replacement in case of quality problems within one year. Ammonia starts the emergency annunciator and hydrogen sulfide starts the emergency annunciator. More surprises await you.....

Ordering hotline: * * * * * QQ: 2953249429 Manager Gong
For more product details, please visit: http://www.keshian.cn

The company has opened online sales channels, and the prices are all network preferential prices. Quality assurance manufacturers sell in batches. Welcome to inquire. In addition, our company can realize automatic control of equipment, DCS system and professional installation personnel according to user needs,

WMKY-2000 chlorine detection startup emergency annunciator is an explosion-proof safety equipment that can continuously detect the concentration of toxic gas. DC 24V Power Supply Power supply to realize uninterrupted detection of chlorine concentration in the environment all day long. It can display and start emergency signal on site. The start emergency signal signal can also be transmitted to the centralized control center (duty room). Connect the computer to store and print data. Start the emergency signal signal to start Solenoid valve Connect the fan. When the chlorine concentration reaches the preset start emergency signal value of the toxic gas detector, it is transmitted to the gas detection start emergency signal controller through the cable, and the start emergency signal controller sends the start emergency signal signal to prompt the on-site staff to take necessary protective measures and drive the exhaust, cut-off and spray systems, It can effectively prevent poisoning accidents caused by toxic gases.

WMKY-2000T chlorine detector is composed of imported high-performance sensor and high speed signal processing module. The weak signal output by the sensor is converted into a signal output proportional to the measured concentration through the signal processing module, which can be easily introduced into DCS, PLC system or other Control system to realize startup emergency signal and control. Use the startup emergency signal controller provided by our company to form a set of gas detection startup emergency signal system.

Detector features:
1. High quality imported electrochemical toxic gas sensor is adopted, with short reaction time and long service life.
2. Rapid response to gas detection and good repeatability; It can detect various toxic gases;
3. The shell of the detector is made of die-casting aluminum alloy, explosion-proof shell, solid and durable, with excellent performance such as waterproof, dust-proof and anti-corrosion.
4. It can output multiple signals according to user needs; For engineering connection with DCS, PLC and other control systems.
5. It is very convenient to debug and test the signal, as long as the round cover of the instrument is opened, it can be operated directly.
6. Lightning protection function; High reliability, accuracy and good anti-interference.
7. Explosion proof design, explosion-proof grade: ExdIICT6, applicable to hazardous areas in Zone 1 and 2.
8. The sensor probe is made of stainless steel, which has the function of anti-corrosion; The filter screen of the sensing element is made of stainless steel particles, with good air permeability and high detection accuracy.

Main technical parameters:
1. Range: 0-100ppm (the range can be customized according to the site needs up to 0-5000ppm).
2. Measurement accuracy: 5% F.S;
3. Detect toxic and combustible gases such as chlorine, formaldehyde and ammonia;
4. Response time: 20~60 seconds, depending on the test composition and range;
5. Repeatability: 3% F.S;
6. Output signal: DC (4 ~ 20) mA;
7. Working power supply: 15~30V DC; (The recommended working voltage is 24VDC and the load resistance is 250 Ω);
8. Service life: more than 5 years; (related to the site environmental conditions);
9. Ambient temperature: (- 30 ~ + 80) ℃;
10 Ambient humidity: 90% RH;
11. Explosion proof grade: ExdIICT6;
12. The signal transmission distance is less than 2000m;
13. Detection range: 15-25m2;
14. Material: cast aluminum alloy stainless steel;
15. Product size: 155 * 140 * 75mm;
16. Weight: ≤ 1.0kg.

Main performance of chlorine start emergency annunciator
◆ It has the function of starting emergency signal storage memory and historical record query
◆ Real time monitoring of detector status, fast response time of starting emergency signal;
◆ Real time judgment of detector status to reduce the occurrence of false start emergency signal;
◆ Prompt the user of fault information and start emergency signal information in the way of sound start emergency signal (start emergency signal sound>60DB);
◆ Real time current signal viewing function, main and standby electric conversion;
◆ With power failure memory function, it can remember and maintain the control parameters and working state before power failure;
◆ One button reset function, simple operation; Automatic fault diagnosis of each channel;
◆ Each detection point is set separately, the emergency signal value of level 1 and 2 can be started, and the number of channels from one to eight can be set arbitrarily;
◆ The explosion-proof control host can be customized according to the site environment.

Technical indicators:
1) Number of sensor channels: point type 1~8 channels or bus type 255 channels
2) Sensor model: WMKY series toxic gas detector
3) Number of linkage routes: 8 or 255
4) Mainframe power consumption: ≤ 5W
5) Operating voltage range: 220VDC ± 15% (50HZ ± 1)
6) Operating ambient temperature: - 40 ℃~70 ℃ (indoor)
7) Signal bus transmission distance: ≤ 1000m
8) Overall dimension: 300mm * 300mm * 110mm
9) Installation mode: wall mounted
10) Total weight is about 1.5KG

Installation mode:

1. Detector wiring mode: the three wire system is used for the split wire detector, and the four wire system is used for the bus detector. The controller is connected by steel pipe shielding.
2. Large wire impedance: the larger wire impedance shall not exceed 2000m when the cross-section is 1.5mm2.
3. If the specific gravity of chlorine gas is greater than that of air, the gas start emergency annunciator shall be installed 30-60cm from the ground
4. During installation, the sensor shall be downward, and the orientation shall not be changed at will.
5. The detector shall not be installed in the place with strong magnetic field interference.
6. For the installation of the system, the manufacturer can provide door-to-door installation, debugging and guidance services according to the user's requirements, and charge corresponding fees as appropriate. The company will irregularly train the user or the construction unit.

I want to comment

Negative comments such as slander, malicious attack, unsubstantiated and non positive energy will be deleted by the administrator. Your comments may be of high reference value to others.

Related comments

Well received
0%
Neutral comment
0%
negative comment
0%
/ Number of records: 98   home page previous page next page Last

Disclaimer: The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legality of the content are the responsibility of the publishing enterprise. www.chinabuildingmaterials. com does not assume any guarantee responsibility for this. In order to protect your interests, we suggest you choose the building materials link member of China Building Materials Network. Friendly reminder: New and old users are requested to strengthen the screening of the authenticity of information and the identity and qualification of its publisher to avoid unnecessary disputes and losses!

Wuxi Keshian Electronic Equipment Co., Ltd

Ordinary members
Certified
  • Enterprise type:

    Building materials enterprises

  • Business model:

    Production and processing

  • Honors and qualifications:

    0 items

  • Main business:

    Combustible gas start emergency annunciator, natural gas start emergency annunciator, combustible gas detector

  • Address:

    No. 108, Qianrong Road, Binhu District, Wuxi, Jiangsu

I want to join

Online inquiry
  • Wuxi Keshian Electronic Equipment Co., Ltd

  • Supply chlorine start emergency annunciator Chlorine leak start emergency annunciator