home page  >  Product supply  >  Security  >  Anti theft and alarm system  >  Anti theft alarm host >Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer
  •  Provide wall mounted fire host, fire smoke detection system with printer

Provide wall mounted fire host, fire smoke detection system with printer

Price

Electric discussion

  • Minimum order quantity: 1 set
  • Location: Shenzhen, Guangdong
  • Price: electricity
  • Total supply: 200000 sets
  • Delivery period: 2 days
  • Release time: 2022-06-22 09:10:01

Tang Zhenqiang: 13510026629 (Please tell me when you contact me“ Building materials network See the information, there will be a discount! Thank you!)

Warm reminder: Consumers are requested to take epidemic prevention measures for international packages. The goods need three licenses and one report for imported goods (supplier's license, entry quarantine certificate, preventive disinfection certificate and NCV nucleic acid test report)

Detailed description

Fire fighting host JB-TB- CA 2000S Angus fire controller

JB-TB-CA2000S fire start emergency signal controller (linkage type):
01. It is a separate fire start emergency signal controller (joint type).
02. The shell is made of metal.
03. Set 6 groups of direct control outputs.
04. Bus communication mode is adopted.
05. The capacity is 2 circuits, with 254 address points for each circuit.
06. LCD is used to display information. 07. It has the function of historical events and information of fire start emergency signal.
08. It has the function of controlling output delay.
09. It has shielding function and can shield parts, and fire sound and light can start the emergency annunciator.
10. It has supervision function.
11. Realize control function through software. summary
JB-TB-CA2000S Fire start emergency signal controller (linkage type) is a new product developed to meet the market demand of the fire industry, which strictly implements the national standards: GB4717-2005 and GB16806-2006.
Main functional features
JB-TB-CA2000S fire start emergency signal controller (linkage type) has fire start emergency signal, fire start emergency signal control, gas fire extinguishing control, fault start emergency signal, shielding, supervision, self inspection, information display and query Power Supply Display, software control and other functions. In case of fire, it can be handled quickly, so that the fire fighting staff can take effective measures to deal with the fire scene in time. And it can intelligently monitor the on-site fire-fighting equipment to realize on-site real-time monitoring.

Functional technical requirements
01. Self inspection
After the assembly is completed, power on the controller, enter the function menu for self inspection after the controller enters the normal working interface, and the instructions of each module of the controller lamp All should be on.

02. Automatic Login
Under the condition that the controller display works normally, connect a group of corresponding input devices and output devices on any circuit. After entering the automatic login interface and completing the login, you should be able to query the relevant information of this group of devices in the circuit corresponding to the circuit components (circuit 1 of circuit module 0).
03. Linkage programming
Enter the linkage programming interface to program this group of equipment in system linkage and direct linkage respectively. Press Save when finished key preservation.

04. Manual and automatic selection
Select manual/automatic mode to automatic mode, and the automatic indicator light will be on; When it is prohibited/allowed to select to the allowed state, the allowed indicator light will be on.

05. Fire alarm test
Make the input equipment simulate the fire alarm start emergency signal state, the controller shall be able to quickly report the fire alarm information, and the controller fire alarm indicator light is on with a rapid prompt tone.

06. Bus linkage start
After the controller starts the emergency signal (a), the output device shall start quickly, and the controller will display the relevant information about the start of the output module, and the controller start indicator light will light up with a prompt tone. At the same time, the bus linkage button corresponding to the device is turned on. (b) The direct linkage output start indicator light corresponding to the equipment shall be on, and the controller can report the direct linkage equipment start information, and there is DC24V output on the start line terminal of the group of direct linkage equipment output terminals.
07. Bus linkage stop
Press the corresponding bus key to input the start/stop key to output the device, which shall stop quickly. The controller displays the information that the output device stops, and the corresponding bus key start indicator will go out.

08. Direct linkage
Press the stop button on the corresponding direct linkage operation card, and there is DC24V output on the stop line terminal of the output terminal of this group of equipment. After release, DC24V disappears, and at the same time, DC24V on the start line terminal will disappear. At the same time, the start indicator on the controller turns off.

09. Fault start emergency signal
The controller has power failure, circuit module failure, open circuit of acousto-optic output terminal detector In case of loss and other problems, an audible and visual signal for fault indication can be sent.
Product technology and parameters
1. Product name: fire start emergency signal controller
2. Overall dimension: 400mm * 300mm * 100mm
3. Product model: linkage type (JB-TB-CA2000S)
4. Service temperature: - 10 ℃~50 ℃
5. Working power supply: AC 220V ± 10% 15% 50Hz
6. Standby power supply: DC 24V
7. Standard: GB4717-2005
8. Weight: 6.2 Kg

I want to comment

Negative comments such as slander, malicious attack, unsubstantiated and non positive energy will be deleted by the administrator. Your comments may be of high reference value to others.

Related comments

Well received
0%
Neutral comment
0%
negative comment
0%
/ Number of records: 98   home page previous page next page Last

Disclaimer: The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legality of the content are the responsibility of the publishing enterprise. www.chinabuildingmaterials. com does not assume any guarantee responsibility for this. In order to protect your interests, we suggest you choose the building materials link member of China Building Materials Network. Friendly reminder: New and old users are requested to strengthen the screening of the authenticity of information and the identity and qualification of its publisher to avoid unnecessary disputes and losses!

Supply Classification

Shenzhen Puzhesi Technology Co., Ltd

Ordinary members
Certified
  • Enterprise type:

    Dealer

  • Business model:

    Production and processing

  • Honors and qualifications:

    0 items

  • Main business:

    Smoke start emergency annunciator, fire detector, gas leakage start emergency annunciator, combustible gas detector, carbon monoxide start emergency annunciator, fire smoke start emergency signal host, fire controller

  • Address:

    507, Floor 5, Shencai Building, North of Fuyong Avenue, Fuyong Street, Bao'an District, Shenzhen, Guangdong

I want to join

Online inquiry
  • Shenzhen Puzhesi Technology Co., Ltd

  • Provide wall mounted fire host, fire smoke detection system with printer