1、 Overview:
Flat soft rubber sleeve Cable (neoprene flat cable) is specially designed and manufactured for special occasions, such as Hoisting machinery , traveling crane, etc. The cable shall not be knotted when bending, and shall be folded neatly. YB, YBF and YBZ products meet the needs of various occasions.
Flat rubber sheathed flexible cable is prepared and produced according to Q1320282 and AQ00-91 standards, and is applicable to mobile electrical equipment with AC rated voltage UO/U of 450V/750V and below. The flat structure is especially suitable for frequent bending occasions. It is not twisted and folded neatly. For example, three categories of products such as lifting machinery, crane, YB, YBF and YBZ can meet the needs of various occasions.
Flat cables are used in various mobile industries such as hoisting, transportation, machinery, electrical, mining, etc. with operating voltage below 450/750V and ambient temperature of - 40~70 ℃ Power device Of Power Supply Connect and control signal lighting, etc. It has the following characteristics: nitrile compound for insulation and sheath. Improve the cable's flexibility, anti-corrosion and cold resistance. Wire ropes can be added on both sides of the wire core or other Load bearing element.
2、 Product use:
Flat cables are used for power connection and control signal lighting of various mobile power devices in industries such as hoisting, transportation, machinery, electrical, mining, etc. with operating voltage below 450/750V and ambient temperature of - 40~70 ℃
Features and uses of flat cable, Widely used in metallurgy, electric power, petrochemical, electronics, automobile manufacturing and other industries;
The flat cable shall comply with the standard flame retardant and fire resistance characteristics test and the requirements of GB12666-90;
3: Product characteristics;
1. Rated AC voltage:
U0/U 0.6/1KV ,
Uo/U=450V/750V
Uo Effective value of voltage between any main body and ground
U Effective value between any two phase conductors
Service voltage:
AC system:<1.1 rated voltage
DC system:<1.5 rated voltage
Higher operating temperature: 180 ℃
Lower ambient temperature: fixed laying - 60 ℃;
Long term working temperature of wire core: ≤ 65 ℃
2. The installation and laying temperature of flat cable shall not be lower than - 25 ℃;
3. Allowable bending radius of cable: the smaller cable is 10 times of the outer diameter of the cable.
4. Product standard: Q/32028AQ001-91
The picture in the following figure shows that the steel wire reinforced YFBPG 3 * 8 * 1 cable is of special model and specification. If there are other special specifications, please provide samples.
4、 Flat cable product name and purpose:
model | name | Allowable temperature rise | Scope of application |
YBP-J | Natural styrene butadiene insulated and sheathed steel wire reinforced copper wire shielded flat cable | 70°C | Indoor oil free place |
YFBPG | Natural styrene butadiene insulated and neoprene sheathed steel wire reinforced copper wire shielded flat cable | 70°C | Outdoor and places with oil pollution |
YBP | Natural styrene butadiene insulated and sheathed copper wire shielded flat cable | 70°C | Indoor oil free place |
YB | Natural styrene butadiene insulated and sheathed flat flexible cable | 70°C | Indoor oil free place |
YBFP | Natural styrene butadiene insulated and neoprene sheathed copper wire shielded flat cable | 70°C | Outdoor and places with oil pollution
The cable is non combustible |
YBF | Natural styrene butadiene insulated and neoprene sheathed flat flexible cable | 70°C |
model | name | Main purpose | YB | Mobile flat rubber sheathed cable | For indoor lifting and transportation Mechanical power cord | YBF | Non combustible moving flat Rubber sheathed cable | It is suitable for outdoor oil contact occasions with weather resistance and non flame retardancy | YBZ | Flame retardant flat rubber sheathed cable | Flame retardant as YBF |
| | model | Section mm2 | Number of cores | YB | 1.5-2.5 | 3、4、5、7、8、10、12 | YBF | 4-6 | 3、4、5 | YBZ | 25-70 | 3、4 |
|
5、 Cross section diagram of flat cable product:
6、 Technical parameters of flat cable:
Specifications | Conductor structure | Cable Reference Data | Small insulation resistance M Ω at 20 ° C |
Upper limit of outer diameter (width × thickness) | Approximate weight | Large DC resistance at 20 ° C |
Number of cores × sectional area mm2 | Number and diameter mm | YB YBF YBZ mm | YB YBF YBZ Kg/Km | Untinned Ω/KM | Tinning Ω/KM | YB YBF | YBZ |
3×4 | 56/0.30 | 19.6×8.9 | two hundred and eighty-five | four point nine five | five point zero nine | fifty | four hundred |
3×6 | 84/0.30 | 22.0×9.9 | three hundred and eighty | three point three zero | three point three nine |
3×10 | 84/0.40 | 27.5×12.0 | six hundred and fifteen | one point nine one | one point nine five |
3×16 | 126/0.40 | 31.1×13.3 | eight hundred and thirty | one point two one | one point two four |
3×25 | 196/0.40 | 38.3×15.8 | one thousand two hundred and thirty | zero point seven eight | zero point seven nine five |
3×35 | 276/0.40 | 42.8×17.6 | one thousand six hundred and five | one point five five four | zero point five six five | forty | three hundred |
3×50 | 396/0.40 | 49.2×20.0 | two thousand two hundred and five | zero point three eight six | zero point three nine three |
3×70 | 360/0.50 | 55.6×22.5 | two thousand nine hundred and sixty-five | zero point two seven two | zero point two seven seven |