Hangzhou Deyue Electronic Technology Co., Ltd. specializes in providing cost-effective medical IT isolation power system (health IT system) ISO-MED427P insulation monitoring start emergency annunciator system, including: ES710 isolation transformer ES0107107TD47 insulation monitor ISO-MED427P transformer STW2 instrument power supply AN450 remote start emergency signal operation terminal MK2007CBM-CN. The health IT system (isolated power supply system) is a power supply system specially designed for health Class 2 sites according to IEC60364-7-710 and GB16895.24-2005, which is mainly composed of health isolation transformer (medical single-phase isolation transformer), insulation monitor (insulation monitor) and external startup emergency signal display device (external startup emergency signal test panel), Its capacity can be selected from 3.15kVA to 10kVA. At the same time, Hangzhou Deyue Electronic Technology Co., Ltd. also provides the instrument power supply dedicated to the health IT system and the external startup emergency signal test panel to synchronously display and monitor the working status of the IT isolated power supply. The medical isolation power supply system used in the operating room, ICUCU and other special occasions must include the following systems a, each Class I operating room should be equipped with no less than 10KVA according to the original design power distribution idea and total load, IT system composed of ≥ 6.3KVA isolation transformer must be set (including isolation transformer, insulation monitor, current transformer, special power supply for instrument, external startup emergency signal display and test unit); The total distribution load of each Level III operating room should not be less than 8KVA, and the IT system should be composed of ≥ 6.3KVA isolation transformers; The larger breaking time of the IT system shall be 0.2S.b. The medical isolation power supply system consists of medical isolation transformer, insulation monitoring, external starting emergency signal device, circuit breaker and other main components, and meets the following standards: 1. The isolation transformer 1.1 meets the requirements of Electrical Installations of Buildings Part 7-710: Requirements for Special Devices or Fields - Health Places GB16895.24-2005/IEC60364-7-710:2002710.512.1.6 stipulates that the medical isolation transformer shall meet the requirements of IEC61558-2-15. 1.2 The rated voltage Un at the secondary side of the transformer shall not exceed 250V. The health IT system used for mobile and fixed equipment shall adopt single-phase transformer, and its rated output capacity shall not be less than 0.5KVA, but not more than 10KVA. 1.3 The metal shell of the medical isolation transformer shall be connected with the local equipotential bonding terminal board. 2 Insulation monitor 3 Start emergency signal display system Medical isolation power supply Medical isolation transformer Medical insulation monitor Leakage monitor (residual current monitor) Leakage monitor system (residual current monitor system) Single phase medical isolation transformer capacity standard is 3150VA 4000VA5000VA6300VA80000VA 10000VA Other capacities can be customized
Zhao Gong
Online contact Mobile: 13588806580
Address: Yuhang District, Hangzhou, Zhejiang