home page  >  Product supply  >  floor  >  Floor accessories  >  Rubber welding wire >Supply S0705-A0401-002
  •  Supply S0705-A0401-002
  •  Supply S0705-A0401-002
  •  Supply S0705-A0401-002
  •  Supply S0705-A0401-002

Supply S0705-A0401-002

Price

Electric discussion

  • Minimum order quantity: 1 volume
  • Location: Fuzhou, Fujian
  • Price: electricity
  • Total supply: 1 roll
  • Delivery period: 1 day
  • Published on: 2014-05-22 08:50:39

Ai Peng: 15659184635 (Please tell me when you contact me“ Building materials network See the information, there will be a discount! Thank you!)

Warm reminder: Consumers are requested to take epidemic prevention measures for international packages. The goods need three licenses and one report for imported goods (supplier's license, entry quarantine certificate, preventive disinfection certificate and NCV nucleic acid test report)

Detailed description

  • Place of Origin:

    Fuzhou

  • Brand:

    Blue macro

  • Grade:

    qualified

  • Standard:

    national standard

  • Specifications:

    Multiple values (mm)

  • Unit of measurement:

    individual

  • texture of material:

    Aluminum alloy solid wood

  • Style:

    other

Continuous flue gas emission measurement (CE MS )System

Fuzhou Lanhong Automation Equipment Co., Ltd. is specialized in CEMS system spare parts. The price is favorable. A large number of stocks are on hand. It has a long-term cooperation relationship with domestic thermal power plant suppliers! Contact: Ai Gong: * * */* * * Fax: * * * - 808

With the development of modern industry, air pollution has attracted more and more attention. All kinds of pollution in the air will not only cause a series of economic losses, but also be closely related to human health and the entire natural environment. CEMS system came into being, which is widely used to monitor the concentration and total emission of gaseous pollutants, and is an indispensable link in the combustion and emission process.

Scope of application:

thermal power plant

technology kiln industrial boiler

Civil heating boiler

Iron and steel alchemy

Waste incineration plant

Petrochemical industry

cement Industry, etc

Main technical features:

(1) The system design is stable and reliable, with low maintenance cost and less maintenance.

(2) The availability rate is above 95%.

(3) Powerful self diagnosis function and emergency signal function for failure of main instrument components, timely feedback information, and easy operation.

(4) The combination of in-line in-situ measurement and decimation analysis can be used.

(5) In situ measurement analyzer has built-in reference cell and automatic calibration function.

(6) The extraction analyzer can use the air automatic calibration function, which is convenient and easy to operate.

(7) Clear (back blowing) air system is used by system components and sampling probe staff to prevent smoke pollution Analysis instrument Component.

(8) Fast isolation door The device can be quickly started under the cute emergency state to protect the monitoring parts.

(9) Anti corrosion design ensures long-term reliable operation of the system.

Concept of cems system

CEMS is the abbreviation of Continuous Emission Monitoring System, which refers to the device that continuously monitors the concentration and total emission of gaseous pollutants and particulates emitted by air pollution sources and transmits the information to the competent department in real time. It is called "automatic flue gas monitoring system", also known as "continuous flue gas emission monitoring system" or "online flue gas monitoring system". CEMS consists of gaseous pollutant monitoring subsystem, particulate matter monitoring subsystem, flue gas parameter monitoring subsystem and data acquisition and processing and communication subsystem. The gaseous pollutant monitoring subsystem is mainly used to monitor the concentration and total emissions of gaseous pollutants SO2, NOx, etc; The particle monitoring subsystem is mainly used to monitor the concentration of smoke and dust and the total emissions; The flue gas parameter monitoring subsystem is mainly used to measure the flue gas flow rate, flue gas temperature, flue gas pressure, flue gas oxygen content, flue gas humidity, etc., and to calculate the total emissions and convert the relevant concentrations; The data acquisition, processing and communication subsystem consists of a data collector and a computer system. It collects various parameters in real time, generates dry, wet and converted concentrations corresponding to each concentration value, generates daily, monthly and annual cumulative emissions, completes the compensation of lost data, and transmits the report to the competent department in real time. Smoke and dust test has developed from cross flue opacity dust meter and β - ray dust meter to plug-in backscatter infrared light or laser dust meter, as well as forward scattering, side scattering and electricity dust meter. According to different sampling methods, CEMS can be mainly divided into three technologies: direct measurement, decimation measurement and remote sensing measurement.
Flue gas: It refers to the waste gas pollution generated by the enterprise in the production process, including SO2 NOx、HCL、CO、CO2、 Particulate matter includes oxygen content, etc.
Discharge: It refers to the process in which enterprises discharge the waste gas generated from production into the atmosphere.
Continuous: It means that the emission of the enterprise is a continuous process and the real-time monitoring of the system is also a continuous process.
monitor: It means that the system can monitor whether the harmful substances in the exhaust gas discharged by the enterprise exceed the standard in real time and automatically transmit the data obtained from the real-time monitoring to the superior department at the same time.
System: It means that the hardware and control software of the product are integrated.

Application of cems products:

The application of this product must have the certification certificate of the national environmental protection department and the measurement production license, etc. At present, it is mainly used in the continuous monitoring of various industrial exhaust emission sources, including thermal power plants, waste incineration power plants, chemical plants, paper mills and other industries, with strong applicability, and can measure SO2 concentration, NOx concentration CO concentration, particle concentration, oxygen content, temperature and humidity, pressure, flow rate and other gas parameters.

I want to comment

Negative comments such as slander, malicious attack, unsubstantiated and non positive energy will be deleted by the administrator. Your comments may be of high reference value to others.

Related comments

Well received
0%
Neutral comment
0%
negative comment
0%
/ Number of records: 98   home page previous page next page Last

Disclaimer: The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legality of the content are the responsibility of the publishing enterprise. www.chinabuildingmaterials. com does not assume any guarantee responsibility for this. In order to protect your interests, we suggest you choose the building materials link member of China Building Materials Network. Friendly reminder: New and old users are requested to strengthen the screening of the authenticity of information and the identity and qualification of its publisher to avoid unnecessary disputes and losses!

Fuzhou Lanhong Automation Equipment Co., Ltd

Ordinary members
Certified
  • Enterprise type:

    Others

  • Business model:

    Distribution and wholesale

  • Honors and qualifications:

    0 items

  • Main business:

    FestoSchneider Siemens

  • Address:

    Fuzhou, Fujian

I want to join

Online inquiry
  • Fuzhou Lanhong Automation Equipment Co., Ltd

  • Supply S0705-A0401-002