Product description
KY-LWGQ type Gas turbine Flowmeter Product features :
The pressure loss is small, and the impeller has Anti corrosion function ;
Advanced ultra-low power consumption single chip microcomputer technology is adopted, with strong functions, low power consumption and superior performance.
Intelligent flow indicator with nonlinear precision compensation function. The accuracy of the correction formula is better than ± 0.02%
The instrument coefficient can be determined by key It can be set online and displayed on the LCD screen, which is intuitive, clear and reliable
EEPROM is used to protect the accumulated flow and instrument coefficient from power failure, and the protection time is more than 10 years
High performance MCU midpoint processor is used to complete data acquisition, processing, display, output, cumulative flow, and instantaneous flow
Convenient human-machine interface for screen display, data transmission in standard 485 form.
All hard alloy (tungsten carbide) shielded cantilever beam structure bearing is adopted, which integrates rotating bearing and pressure bearing
The bearing life is greatly improved, and it can work in the medium with a small amount of sediment and dirt.
use 1Cr18Ni9Ti all stainless steel Structure( turbine 2Cr13) has good anti-corrosion performance.
It is easy to maintain, has a self rectifying structure, small and light, simple structure, and can be combined and disassembled in a short time,
Internal cleaning is simple.
It has strong anti magnetic interference and vibration ability, reliable performance and long service life
Low lower limit flow rate, wide measurement range,
On site LCD display is clear and intuitive, low power consumption, 3V lithium Battery The power supply can operate continuously for more than 5 years,
Corrosion resistance, suitable for acid and alkali solutions
Gas turbine flowmeter technical parameter
Nominal diameter: The Conduit Type: DN4 ~ DN200
Plug in type: DN100 ~ DN2000
Accuracy class: pipeline type: ± 0.5, ± 1.0
Plug in type: ± 1.5 level, ± 2.5 level
Ambient temperature: - 20 ℃~50 ℃
Medium temperature: measuring liquid: - 20 ℃~120 ℃
Measuring gas: - 20 ℃~80 ℃
Atmospheric pressure: 86KPa ~ 106KPa
Nominal pressure: 1.6 Mpa, 2.5 Mpa, 6.4 Mpa, 25 Mpa
Explosion proof grade: ExdIIBT4
Connection mode: threaded connection flange Clamp mounting, flange connection, plug-in type, etc
Requirements for straight pipe section: gas: the upstream straight pipe section shall be ≥ 10DN, and the downstream straight pipe section shall be ≥ 5DN
Liquid: the upstream straight pipe section shall be ≥ 20DN, and the downstream straight pipe section shall be ≥ 5DN
Plug in type: the upstream straight pipe section shall be ≥ 20DS, and the downstream straight pipe section shall be ≥ 7DS (DS is the measured inner diameter of the pipe)
Display mode: (1) Remote display: pulse output, current output (equipped with display instrument)
(2) Field display: 8-digit LCD displays cumulative flow, unit (m3)
4-digit LCD displays instantaneous flow, unit (m3/h), battery power, frequency and flow rate
(3) Temperature and pressure compensation type:
A、 Display standard instantaneous flow and standard cumulative flow
B、 Display the current pressure, temperature and battery voltage
Output function:
(1) Pulse output, p-p value is determined by power supply
(2) 4~20mA two-wire current output
(3) Pulse output per unit volume and original pulse output of sensor
(4) With RS485 communication interface
Power supply:
(1)DC5~24V
(2) The standard 3V lithium battery installed inside the instrument can be used continuously for more than eight years
(3) Temperature and pressure compensated 3V lithium battery installed inside the instrument can be used continuously for more than four years
Transmission distance: the distance from sensor to display can reach 500m
Gas turbine flowmeter Selection tips
choose Gas turbine flowmeter The following parameters need to be determined in detail: pipe diameter, measuring medium, working temperature, pressure
Force (working state or standard state), installation mode (pipeline or plug-in), power supply (12V, 24V or battery
Power supply), output mode (4-20mA, pulse output or 485 communication), large flow (working state or standard state),
Explosion proof is required, and companion flange is required for flange connection type.
Gas turbine flowmeter Flow range under working condition (unit: m3/h), see the table |
|
Flow range diameter | twenty-five | thirty-two | forty | fifty | eighty | one hundred | one hundred and fifty | two hundred | two hundred and fifty | three hundred | Gas | 2-25 | 3-40 | 5-65 | 5-120 | 15-350 | 20-500 | 45-900 | 80-1800 | 125-2800 | 200-4800 |
|