100KW silent diesel generator GT-100TSI Can you operate and work normally without electricity? Power failure will definitely bring great impact and inconvenience to your work and life. At this time, do you need a generator? It will solve your problems, ensure your normal work and life, and reduce the loss caused by power failure!

Common faults that the mute generator cannot generate electricity:
(1) Wiring errors shall be checked and corrected according to the circuit diagram.
(2) The excitation winding of the main generator or exciter is wrongly connected, resulting in incorrect polarity. It is often caused by wiring error after replacing the quiet generator with excitation winding. It shall be checked and corrected.
(3) The rotating silicon rectification element is broken down and short circuited, and the positive and negative directions are connected. Use a multimeter to check the forward and reverse resistance of the rectification element and replace the damaged element.
(4) The excitation winding of the main generator is disconnected. Check and measure the excitation winding of the main generator with a multimeter. The resistance is infinite. Connect the excitation circuit.
(5) Each winding of the main generator or exciter is severely short circuited, and the armature winding is short circuited, 100KW silent diesel generator GT-100TSI Generally, obvious overheating and short circuit of excitation winding can be determined by the resistance value of its branch current. Replace the damaged winding. The company specializes in silent generator sets, power generation welding machines and silent generator sets.

  100KW silent diesel generator GT-100TSI


GT-100TSI

 

1、 Technical Specifications

Rated output  100KVA    

Standby power  110KVA   

Rated frequency: 50Hz

Rated voltage: 400V

Rated speed: 1500

Generator type: Mute

Startup mode:   Electric starting

mutually     Number: three-phase

Power factor: COS Φ=0.8 (lagging)

 

Noise level LP7m: 72-85db/7M

Steady state voltage adjustment: (%): ≤± 0.5

Voltage fluctuation: (%): ≤± 0.5

Load sudden change voltage %: ≤±2

Steady state frequency adjustment %: ≤±2

Engine technical parameters:

Power model: GT-100

Cylinder arrangement: in-line

Number of cylinders: 6 cylinders

Cooling mode:   Closed water circulation cooling

Oil supply mode:   Direct injection combustion type

Speed regulation mode:   Mechanical speed regulation

Silencer: industrial silencer

Air intake mode:   Turbo

Oil type: SAE10W30 (or CD)

Fuel model: 0 # - 10 # diesel

Diesel oil tank: 150L

Unit fuel consumption: 224g/kw • h

Technical parameters of motor :

Rated power:  100KW

Wiring mode:   Three phase four wire Y-connection

Protection grade:  IP22

Insulation class: Level H

Motor type: brushless motor

Other configurations:

Overall dimensions of unit( L×B×H):2950*1100*1570mm
Unit weight( kg):1500/1650

Disclaimer: Hangzhou Shangyi Information Technology Co., Ltd. does not declare or guarantee the correctness or reliability of all information published on CNBM Online; You hereby accept and acknowledge that you shall bear the risk arising from reliance on any information. Hangzhou Shangyi Information Technology Co., Ltd. has the right but not the obligation to improve or correct errors or omissions in any part of the information published.

News classification

Shanghai Ciman Power Equipment Co., Ltd

Building Materials General

six year

Certified
  • Enterprise type:

  • Business model:

    Business services

  • Honors and qualifications:

    0 items

  • Main business:

    Mute diesel generator

  • Address:

    Room J2767, Building 1, No. 2222, Huancheng Road, Juyuan New District, Jiading District, Shanghai, Fengxian District, Shanghai

I want to join

 Personal WeChat