  • How to calculate cable fireproof coating

    How to calculate the cable fireproof coating? The calculation of cable fireproof coating is 1.2 * 103/m3. One square meter of cable is brushed with 1m2/1.2kg of fireproof coating. Wg=K ×π× D × LWg - coating amount (kg); D --- Cable outer diameter (m); L --- brushing length (m); K - unit consumption (kg/m) When the coating thickness is 0.8mm, K is taken as 2; When the coating thickness is 1.0mm, K is taken as 2.5; When the coating thickness is 1.2mm, K is taken as 3 for the construction of cable fireproof coating. 1. Before the construction of cable fireproof coating, the floating dust, oil, etc. on the cable surface shall be removed

    2019/05/06 21:16:02
  • Thickness of fireproof coating for steel structure with first class fire resistance rating

    The thickness of fireproof coating for steel structure of the first level fire resistance rating is 3h. The thickness of fireproof coating for steel structure is 23mm. The thickness of thin fireproof coating for steel structure can be used for 2.5h. The thickness of coating is only 4.7mm. The first level fire resistance rating for general buildings requires 3h for steel columns, 2.5h-2.0h for steel beams, and 2.0-1.0h for accessories. The fireproof coating can be used separately. 1. Ultra thin fireproof coating for steel structure, with coating thickness less than or equal to 3mm. 2. Thin steel structure fireproof coating, with coating thickness greater than 3mm and less than or equal to 7mm. 3. Thick

    2019/05/06 00:16:24
  • Ultra thin fireproof coating manufacturer Steel structure 3c approved fireproof coating company

    Ultra thin fire-retardant coating manufacturer Steel structure 3c approved fire-retardant coating company Steel structure ultra-thin fire-retardant coating oil and water manufacturers, national standard steel structure 3c approved fire-retardant coating company, ultra-thin steel structure fire-retardant coating products are divided into water and oil (solvent). When exposed to fire, the foaming component in the coating film of the product is decomposed by heat, and the expansion and thickening produce a dense and uniform fireproof and thermal insulation protective layer, which can generate decomposition endothermic reaction, prevent heat transfer, delay the temperature rise of the steel structure, and greatly improve the fire resistance time of the steel structure. The coating is a kind of steel structure with good expansion and thermal insulation performance under fire and good decorative performance

    2019/05/04 23:05:26
  • Price of fire prevention mud * * * fire prevention plugging mud

    The price of fire prevention and fire prevention putty * * * fire prevention and fire prevention plugging putty, the wholesale price of fire prevention and fire prevention plugging putty * * * by Yinuo Fire Prevention and Fire Prevention Mud Factory, is one ton of fire prevention and fire prevention plugging putty. This product is a * * * halogen free fire prevention plugging material, mainly made of * * * temperature refractory clay and * * * adhesive, and has the characteristics of water resistance, fire resistance, * * * temperature resistance, acid and alkali resistance, flame retardancy, etc, It is mainly used in the fire blocking engineering of building pipes and wire and cable penetration holes, and is used together with inorganic fire blocking materials and fire retardant packages. Performance index Appearance density Water resistance Oil resistance Corrosion resistance Fire resistance Plastic solid with certain flexibility 2.0 × 103kg

    2019/05/03 23:02:42
  • How much does the national standard fire retardant package usually cost per ton

    How much does the national standard fire retardant package cost per ton? The national standard fire retardant package generally costs 2000-5000 yuan per ton. The manufacturer's wholesale fire retardant package is cheap. It can also customize various specifications of fire retardant packages. This product can be built into various shapes of firewalls and fireproof layers according to the different requirements of users, and can also seal the holes that need fire prevention treatment. It is convenient for construction. In case of fire, the materials in the fire bag will expand due to heat and form a honeycomb block, effectively controlling the fire within the local scope.

    2019/05/02 22:23:41
  • How many fire arresters are required per square meter 720 density of fire arresters

    Several fire arresters per square meter The density of 720 fire arresters is 06 * 103/m3, the density of 500 fire arresters per cubic meter, and the standard size of 720 fire arresters is 320 * 180 * 40mm. This product is mainly used for fire blocking of various cable penetration holes in the power, communication, petrochemical, construction, shipbuilding and other industries, which can effectively prevent the fire from spreading along the cable, It can largely avoid the loss of life and property. The product has good ventilation, acid and alkali resistance, water resistance, oil resistance, light weight, easy to use and other characteristics at room temperature, and can rapidly expand and carbonize when exposed to fire

    2019/05/02 00:13:31
  • Fire retardant coating construction cable process Spraying fire retardant coating

    Fire retardant coating construction cable process spraying fire retardant coating construction method of cable fire retardant coating: 1. Before the construction of cable fire retardant coating, the floating dust, oil stain, sundries, etc. on the cable surface shall be cleaned and polished, and the construction of fire retardant coating can be carried out after the surface is dry. 2. Spraying, brushing and other methods shall be adopted for the construction of cable fireproof coating, which shall be fully stirred and evenly used. When the coating is slightly thick, it can be diluted with appropriate amount of tap water to facilitate spraying. 3. During construction and before the coating is dry, it shall be waterproof, sun proof, anti pollution, anti movement and anti bending. If there is any damage, it shall be repaired in time. 4. For wires with plastic and rubber skins

    2019/05/01 00:04:17
  • Technical requirements for construction process of power plant cable fireproof coating

    Technical requirements for construction process of fire retardant coating for power plant cables GB50168 Code for construction and acceptance of cable lines of electrical equipment installation engineering GB50217 Code for cable design of power engineering GB23864-2009 Fire blocking materials GB12441-2005 Decorative fire retardant coating CECS154-2003 Technical specification for application of building fire blocking DL/T5161 Specification for Quality Inspection and Assessment of Electrical Equipment Installation Engineering. DL/T5221 Technical Code for Design of Urban Power Cable Lines DLGJ154

    2019/05/01 00:02:52
  • Cable fireproof coating density * * * good or low

    The density of cable fireproof coating is * * * good or low. The density of cable fireproof coating is 1.2/m2 according to the national standard. The cable fireproof coating is used on the surface of combustible substrate, which can reduce the flammability of the surface of the coated material and prevent the rapid spread of fire. It is a special coating used to improve the fire resistance limit of * * * the coated material. Fireproof coating applied on the surface of the base material, in addition to its flame retardancy, also has the properties of rust prevention, waterproof, anti-corrosion, wear resistance, heat resistance, as well as the toughness, coloration, adhesion, dryness and glossiness of the reinforcement material, which can effectively prevent the spread of fire. The coating has good fire and moisture resistance, acid and alkali resistance, and oil resistance

    2019/05/01 00:00:04
  • ***Fireproof sealing construction of pressing cable with several times of fireproof coating

    ***Fire blocking construction by brushing fire retardant coating several times for cable pressing * * * Fire retardant coating can be brushed 3-5 times for cable pressing to ensure that the thickness of cable fire retardant coating is more than 1mm. The definition of fire retardant coating is applied to the surface of combustible substrate to change the burning characteristics of material surface and prevent the rapid spread of fire; Or the special coating applied to building components to raise the fire resistance limit of * * * components is called fire retardant coating. Fire retardant coating can improve the fire resistance of * * * materials, slow down the spread of flame, or prevent combustion within a certain period of time by brushing the coating on the surface of those combustible materials

    2019/04/30 23:58:36

News classification

Cangzhou Yinuo Fireproof Materials Co., Ltd

Building Materials General

seven year

Certified
  • Enterprise type:

    Building materials enterprises

  • Business model:

    Production and processing

  • Honors and qualifications:

    1 item

  • Main business:

    Steel structure fireproof coating, cable fireproof coating, fireproof bag, fireproof mud, fireproof board, fireproof module, fireproof sealant, fireproof cloth

  • Address:

    Hebei Cangzhou Hejian Wofo Hall

I want to join

 Personal WeChat