¥ ElectricityModel: S-Sorb X700Updated on: April 24, 2024Product Catalog
Vapor adsorber s-sorb x700 is a device for measuring the isothermal adsorption curve of water and organic vapor, which can test the adsorption and desorption amount, adsorption and desorption speed and other parameters of materials to water vapor, organic vapor and various gases.The equipment uses stainless steel pipe to connect through vcr interface to improve the vacuum degree of the pipe.The core system device maintains constant temperature at 125 ℃, has a pressure resistant and corrosion resistant steam generator, and the system air leakage rate is as low as 1x10-11 pa.m3/s.It can be widely used in food, medicine, water purification and other industries
¥ ElectricityModel: VstarUpdated on: April 23, 2024Product Catalog
Anton Pacanta full-automatic vapor adsorption analyzer vstar is a new star in Anton Pacanta precision adsorption analyzer product line!Beyond water adsorption applications, vstartm can use a variety of organic vapors, providing full automation in a wide temperature range
The cdm2e32-160z cylinder is available from stock, the internal thread at the rod end is standardized, the operability of the magnetic switch is improved, and the position is easy to adjust. The single ear ring type and trunnion type swing bases are provided, and the models of rod end mounting parts and swing base mounting parts are set (to save the time of ordering the cylinder and mounting parts respectively) with magnetic switches.
¥ ElectricityModel: BSD-PWPUpdated on: March 26, 2024Product Catalog
With the rapid development of petrochemical industry, medicine and environmental protection, researchers have more and more demands for low vapor pressure data.For example, the storage of pesticides and fertilizers, the manufacture of flavors and fragrances, and the prolongation of the life of plasticizers in rubber and plastics require the low vapor pressure data of pure substances for the design and development of these products, so it is of great significance to test the low vapor pressure.The current situation is that most of the steam pressure data are concentrated in the range of more than tens of pascals, and there are few low pressure and ultra-low pressure data. How to accurately test the low steam pressure data of pure substances is exactly what this instrument can do for everyone.
¥ ElectricityModel: BSD-PMVUpdated on: March 26, 2024Product Catalog
The principle of static volumetric method, based on the classical volumetric physical adsorption instrument, can not only meet the requirements of conventional gas adsorption, low-temperature nitrogen adsorption, specific surface and pore size testing, but also achieve the requirements of steam adsorption evaluation testing at a low cost by adding steam reagent source, anti condensation thermostatic device, etc.
¥ Electricitymodel:Updated on: March 18th, 2024Product Catalog
The German headquarters directly purchases kuhme steam valves, original products, good delivery time, support model selection, and provide you with the right solution: Herna Dalian has 10 offices in China, which can provide you with good maintenance services.
¥ ElectricityModel: Steam-1010Updated on: March 4, 2024Product Catalog
Steam-1010 static vapor gas adsorption analyzer is an instrument for characterizing the vapor adsorption experiment of nanomaterials. It also has the capability of low-temperature nitrogen adsorption experiment (bet, pore size analysis). It has advanced technology, excellent quality, a more comprehensive theoretical model and excellent test accuracy to meet the needs of scientific research, academic discussion and other applications
3h-2000pw gravimetric vapor adsorption tester, the first vacuum multistation gravimetric vapor adsorption tester in the world, is a research grade analytical instrument. The amount of specific vapor and gas adsorbed and desorbed by samples is measured by weighing the weight changes of samples before and after adsorption and desorption under a certain relative partial pressure with a microbalance.
With the rapid development of petrochemical industry, medicine and environmental protection, researchers have more and more demands for low vapor pressure data.For example, the storage of pesticides and fertilizers, the manufacture of flavors and fragrances, and the prolongation of the life of plasticizers in rubber and plastics require the low vapor pressure data of pure substances for the design and development of these products, so it is of great significance to test the low vapor pressure.The current situation is that most of the steam pressure data are concentrated in the range of more than tens of pascals, and there are few low pressure and ultra-low pressure data. How to accurately test the low steam pressure data of pure substances is exactly what this instrument can do for everyone.
The 3h-2000ph full-automatic high-precision high-pressure adsorption instrument is a research level instrument, which can meet the requirements of high-temperature and high-pressure adsorption and desorption test of various gases. It can test the total adsorption capacity, adsorption constant and other parameters of various materials for different gases under different pressures. It is suitable for scientific research institutions and enterprise users studying the adsorption performance of high-pressure gases, such as molecular sieves, coal bed methane, hydrogen storage materials, etc.The all stainless steel gas circuit system adopts vcr hard connection to ensure the high vacuum degree and high sealing performance of the instrument. it is a typical product with high performance and stability.
¥1000000.00model:Updated on: November 6, 2023Product Catalog
Gravimetric adsorption instrument is a research and analysis instrument. The amount and speed of adsorption and desorption of samples to specific steam and gas are measured by weighing the weight change of samples after adsorption and desorption under a certain relative partial pressure with a microbalance.Compared with the volumetric method, no compromise approximation is adopted, and there are no error sources such as temperature free zone distribution, gas non idealization correction, etc.The volumetric method can not test the real-time isobaric adsorption rate and accurately describe the adsorption kinetic characteristics of materials;In the vacuum gravimetric vapor adsorption instrument, it is a global multi station instrument, which can support simultaneous analysis of 1-8 analysis stations.
¥ ElectricityModel: QT106 - HD-2003Updated on: June 28, 2023Product Catalog
Features: small lead chamber, high sensitivity, equipped with activated carbon capture device and working correction source, data storage and playback function, standard USB communication interface
¥ ElectricityModel: ATDS-20AUpdated on: May 20, 2024Product Catalog
Atds-20a low temperature cold trap full-automatic secondary thermal desorption/thermal analyzer is a new generation product independently developed and launched by the Spectral Analysis Instrument Manufacturing Hebei Co., Ltd., which is directly oriented to domestic and foreign users.The instrument is suitable for qualitative and quantitative detection of various gases with boiling points below 350 ℃ in chemical building materials, food, atmosphere and indoor environment. It can be connected with any domestic and foreign gas chromatograph and gas chromatograph. Its automation, repeatability, sensitivity and other indicators can meet the current national standards for environmental detection,And it has its own unique functional advantages in structure and satisfactory performance price ratio.Fully automatic design, large touch screen display, and more convenient operation. It can continuously run a new generation of full-automatic thermal desorption instrument with 20 samples.
¥ ElectricityModel: d301Updated on: September 25, 2023Product Catalog
Palladium adsorption resin product price Strong acid cation resin This product is specially developed for the electroplating industry to recover gold from gold plating solution. It is mainly used for the recovery of gold from gold plating solution (gold cyanide and gold cyanide solution
¥ Electricitymodel:Updated on: September 8, 2023Product Catalog
1、 Enzyme linked immunosorbent test liquid sample: 1. Serum: collect whole blood with a pp tube (excluding pyrogen and endotoxin), coagulate naturally at room temperature for 20-30 minutes, or stay at 4 ℃ overnight, and separate the bleeding serum (properly tilt the centrifuge tube to expand the cross section of the liquid surface, so that the serum can be larger
¥ Electricitymodel:Updated on: August 25, 2023Product Catalog
At present, there are many ways to purify organic waste gas in China for the activated carbon adsorption equipment of Suzhou activated carbon adsorption box manufacturer, such as direct incineration, catalytic incineration, regenerative incineration (rto, rco), etc., but it is difficult to incinerate waste gas with low concentration and large air volume, and the waste heat cannot be fully utilized in intermittent operations.About low concentration and large
¥ ElectricityModel: SZLY-1000Updated on: May 9, 2023Product Catalog
Szly-1000 intelligent steam distiller (dual-use) is applicable to the extraction of plant active ingredients that are volatile, can not be destroyed with steam distillation, stable in water and insoluble or insoluble in water.A distillation method in which water vapor is directly injected into a liquid mixture that is not miscible with water.Main technical points: 1
¥ ElectricityModel: 7000 seriesUpdated on: May 5, 2023Product Catalog
7000 series water vapor transmittance analyzer modular system is used for accurate water vapor transmittance test of packaging film obstacles.The systech illinois 7000 water vapor analyzer series uses a sensitive and stable p2o5 sensor to measure the water vapor transmission.The water is steamed
¥ ElectricityModel: 3FlexUpdated on: 2023-2-13Product Catalog
3flex gas adsorber Introduction of 3flex gas adsorber As an instrument in the field of material physical property characterization, 3flex full-featured multi-purpose gas adsorber can provide high-precision adsorption and desorption isotherm data, providing strong data support for the whole process from basic research to method verification to process improvement.
¥ ElectricityModel: VSTAR™Updated on: 2023-2-13Product Catalog
Vstar ™ full-automatic vapor adsorption analyzer is a new star in the precision adsorption analyzer product line of Conta Instruments!Beyond water adsorption applications, vstar ™ can use a variety of organic vapors to provide fully automatic vapor adsorption analysis over a wide temperature range.Fine control of manifold temperature in a wide range from steam source to sample eliminates the possibility of local condensation of adsorbed substances, and ensures the most accurate analysis process to the maximum extent
¥ ElectricityModel: VSTAR™Updated on: 2023-2-13Product Catalog
Anton Pacanta vapor adsorption analyzer vstar™It is a new star in the product line of precision adsorption analyzer of Anton Pacanta Instrument Company!Beyond water adsorption applications, vstar ™ can use a variety of organic vapors to provide fully automatic vapor adsorption analysis over a wide temperature range.The fine control of manifold temperature in a wide range from the steam source to the sample eliminates the possibility of local condensation of the adsorbed material and ensures the most accurate analysis process.
¥ ElectricityModel: BSD-PWPUpdated on: December 27, 2022Product Catalog
With the rapid development of petrochemical industry, medicine and environmental protection, researchers have more and more demands for low vapor pressure data.For example, the storage of pesticides and fertilizers, the manufacture of flavors and fragrances, and the prolongation of the life of plasticizers in rubber and plastics require the low vapor pressure data of pure substances for the design and development of these products, so it is of great significance to test the low vapor pressure.The current situation is that most of the steam pressure data are concentrated in the range of more than tens of pascals, and there are few low pressure and ultra-low pressure data. How to accurately test the low steam pressure data of pure substances is exactly what this instrument can do for everyone.
Member service consultation: 0571-85363692 Customer service hotline: 0571-85363692 Purchase hotline: 0571-85363691 Purchase technology exchange group number: 187637045