home page  >  News Center  >  Corporate News >Natural gas flowmeter

Natural gas flowmeter

2019/1/4 17:20:50 Source: Weinan High tech Zone and Shunda Mechanical and Electrical Equipment Co., Ltd Views: one thousand six hundred and sixty-nine

Model of Hesunda's new VN series flowmeter: VN-15, VN-25, VN-45, VN-50, VN-80, VN-100, VN-125, VN-150, VN-200 and other VN flowmeter products provide users with a series of flow measurement instruments, such as gas flowmeter, gas target flowmeter, blast furnace gas_coke oven gas flowmeter, biogas flowmeter, natural gas flowmeter, heavy oil flowmeter, sewage flow meter, etc.

1、 Main features and technical parameters of VN natural gas flowmeter
The overall structure design of the instrument is reasonable, the dynamic measurement range is wide, and the pressure loss is small;
The main body of the instrument can be made of stainless steel, which is suitable for measuring corrosive media;
The instrument has no movable parts and is easy to install and maintain;
On site LCD display, pulse, 4-20mA output or 485 serial communication interface, which can be connected with industrial automation system;
Electrical interface: internal thread M20 × 1.5;
Explosion proof grade mark: iaIICT2 ~ T6;
Protection grade: IP65;
Power supply: built-in power supply (3.6V battery), external power supply 12VDC, 24VDC;
High temperature of measuring medium: 350 ℃;
Working environment temperature: - 30 ℃~+55 ℃; (0 ℃~+55 ℃ for pressure compensation)
Working pressure: 1.6MPa, 2.5MPa, 4MPa, 6MPa, 10MPa, 16MPa, 20MPa, 25MPa, 30MPa, 40MPa;
Accuracy: Grade 0.5, 1.0 and 1.5.
Nominal diameter:
Snap on type: DN10 DN15、DN20、DN25、DN32、DN40、DN50、DN65、DN80、DN100、
DN125、DN150、DN200、DN250、DN300;
Plug in type: DN350, DN400, DN450, DN500, DN550, DN600, DN700, DN800, DN900, DN1000, etc;
Flange type: DN15 DN20、DN25、DN32、DN40、DN50、DN65、DN80、DN100、DN125、DN150、DN200、DN250、DN300。
Higher medium temperature: medium temperature type is less than or equal to 280 ℃, and high temperature type is more than 280 ℃
Higher working pressure: 1.6MPa~40MPa.
Accuracy: 1.0 and 1.5.
Explosion proof grade: ExdIIBT4.
Protection grade: IP65.
Ambient temperature: - 40 ℃~+55 ℃ (0 ℃~+55 ℃ for pressure compensation).
Specifications:
a、 Threaded type, clamp type and flange type: DN10~DN32.
b、 Clamp type and flange type: DN40~DN300.
c、 Plug in type: DN350~DN1000.

 

2、 Advantages of VN natural gas flowmeter
◆ The great advantage of natural gas flowmeter is its excellent anti vibration performance, noon zero drift and high reliability
◆ Extremely good anti vibration performance
A lot of waveform analysis and spectrum analysis are conducted for vortex flowmeter for a long time. SIA has designed a better probe shape, wall thickness, height, probe rod diameter and matching piezoelectric crystals, which are processed with advanced CNC lathe to ensure the coaxiality and smoothness of processing and other technical parameters. Cooperate with special process treatment. So as to largely overcome the common problem that the inherent self oscillation frequency of vortex flowmeter affects the signal. This is the unique technical advantage of Singapore Airlines in manufacturing vortex flowmeter. The vortex flowmeter manufactured by SIA has excellent anti vibration capability.
◆ The sensor of natural gas flowmeter has strong versatility, which makes the sensor have good interchangeability. Advanced numerical control equipment is used to process the sensor body and vortex sounder to ensure the processing accuracy, so that the parts (especially vortex sounder) are universal, so that the repeatability and accuracy of the sensor will not be affected by the replacement of parts, and a strong and stable vortex signal can be generated.
◆ Simple and firm structure, no movable parts, high reliability, convenient function and maintenance.
◆ The detection element is not in contact with the medium, with stable performance and long service life.

 

3、 Precautions for purchase and selection of natural gas flowmeter:
The selection of flow meters often plays an important role in the successful use of the meters. Because of the complex conditions of the tested objects, the wide variety of meters, and the performance indicators, it is difficult to select the type of meters. There is no perfect flowmeter, and all kinds of instruments have their own characteristics. The purpose of model selection is to choose the more appropriate instrument among many varieties.
The general selection can be considered from five aspects, including instrument performance, fluid characteristics, installation conditions, environmental conditions and economic factors.
The detailed factors of the five aspects are as follows:
a. Instrument performance
Accuracy, repeatability, linearity, range, flow range, signal output characteristics, response time, pressure loss, etc;
b. Fluid characteristics
Temperature, pressure, density, viscosity, chemical corrosion, abrasiveness, scaling, miscibility, phase change, conductivity, sound velocity, thermal conductivity, specific heat capacity, isentropic index;
c. Conditional aspects
Pipeline layout direction, flow direction, length and diameter of straight pipe sections at upstream and downstream sides of the test piece, power supply, grounding, auxiliary equipment (filter, degasser), installation, etc. in the maintenance space;
d. Environmental conditions
Ambient temperature, humidity, electromagnetic interference, safety, explosion-proof, pipeline vibration, etc;
e. Economic factors
Instrument purchase cost, installation cost, operation cost, calibration cost, maintenance cost, instrument service life, spare parts, etc.

4、 The selection steps of natural gas flowmeter are as follows:
1. The available instrument types shall be preliminarily selected according to the fluid type and five considerations (several types shall be available for selection);
2. Collect data and price information of the primary type to prepare conditions for in-depth analysis and comparison;
3. The elimination method is used to gradually focus on one or two types, and the pre selection goals should be determined after repeated comparison and analysis of the five factors

5、 Installation conditions of natural gas flowmeter

1. The sensor should be installed on a horizontal, vertical, inclined (liquid flow from bottom to top) pipe with the same diameter. The upstream and downstream of the sensor shall be equipped with straight pipe sections of certain length, which shall meet the requirements of 15~20D for the front straight pipe section and 5~1OD for the rear straight pipe section.

2. The pipeline near the liquid sensor shall be filled with the measured liquid.

3. The sensor shall not be installed on the pipeline with strong mechanical vibration.

4. The inner diameter of the straight pipe section should be consistent with the sensor diameter as much as possible. If not, a pipe slightly larger than the sensor diameter should be used, with an error of ≤ 3% and no more than 5mm.

5. If the measured medium contains many impurities, a filter shall be installed beyond the length required by the straight pipe section upstream of the sensor.

6. The sensor shall not be installed in places with strong electromagnetic interference, small space and inconvenient maintenance.

 

6、 Contact information of natural gas flowmeter:

Contact: * * * Zhang Wei

Tel:***

Contact Fax:***

More information on http://www.hsdyb.com/ Hesunda natural gas flowmeter

Disclaimer: Hangzhou Shangyi Information Technology Co., Ltd. does not declare or guarantee the correctness or reliability of all information published on CNBM Online; You hereby accept and acknowledge that you shall bear the risk arising from reliance on any information. Hangzhou Shangyi Information Technology Co., Ltd. has the right but not the obligation to improve or correct errors or omissions in any part of the information published.

News classification

Weinan High tech Zone Heshunda Mechanical and Electrical Equipment Co., Ltd

one year

Certified
  • Enterprise type:

    Others

  • Business model:

    Production and processing

  • Honors and qualifications:

    0 items

  • Main business:

    Gas flowmeter, biogas flowmeter, steam flowmeter, heavy oil flowmeter, coal water slurry flowmeter, asphalt flowmeter, mortar flowmeter

  • Address:

    Weinan, Shaanxi

I want to join